Background: Early and effective detection of Mycobacterium tuberculosis (MTB), particularly in smear-negative tuberculosis (TB), is a priority for global TB control. Loop-mediated isothermal amplification with a procedure for ultra rapid DNA extraction (PURE-LAMP) can detect TB in sputum samples rapidly and with high sensitivity and specificity. However, the PURE-LAMP test has not been effectively evaluated, especially in resource-limited laboratories. In this study, we evaluated the performance of the PURE-LAMP test for TB detection in TB suspects from two county-level TB dispensaries in China.

Methodology/principal Findings: From April 2011 to February 2012, patients with suspected TB were continuously enrolled from two county-level TB laboratories in China. Three sputum samples (spot, night, and morning sputum) were collected from each recruited patient. Detection of MTB by PURE-LAMP was compared to a reference standard L-J culture. The results showed that the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection was 70.67%, while the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection in smear positive and culture positive patients and smear negative and culture positive patients was 92.12% and 53.81%, respectively. The specificity of PURE-LAMP based on spot sputum for MTB detection was 98.32%. The sensitivity and specificity of the PURE-LAMP test based on three sputa combination for MTB detection was 88.80% and 96.86%, respectively. The results also showed that the PURE-LAMP test had a significantly lower contamination rate than did solid culture.

Conclusions/significance: The study suggested that, in peripheral-level TB laboratories in China, the PURE-LAMP test showed high sensitivity and specificity for TB detection in TB suspects, making it a more effective, rapid, and safe method worthy of broader use in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4006777PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0094544PLOS

Publication Analysis

Top Keywords

pure-lamp test
32
mtb detection
16
sensitivity specificity
12
specificity pure-lamp
12
test based
12
based spot
12
spot sputum
12
sputum mtb
12
pure-lamp
11
test
8

Similar Publications

Background: Early and effective detection of Mycobacterium tuberculosis (MTB), particularly in smear-negative tuberculosis (TB), is a priority for global TB control. Loop-mediated isothermal amplification with a procedure for ultra rapid DNA extraction (PURE-LAMP) can detect TB in sputum samples rapidly and with high sensitivity and specificity. However, the PURE-LAMP test has not been effectively evaluated, especially in resource-limited laboratories.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!