A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Note: neutron bang time diagnostic system on Shenguang-III prototype. | LitMetric

Note: neutron bang time diagnostic system on Shenguang-III prototype.

Rev Sci Instrum

Research Center of Laser Fusion, China Academy of Engineering Physics, P. O. Box 919-986, Mianyang, Sichuan 621900, China.

Published: April 2014

AI Article Synopsis

  • A neutron bang time (NBT) diagnostic system has been installed on the Shenguang-III prototype to measure the timing of neutron production during fusion events.
  • The system utilizes a combination of a plastic scintillator and a micro-channel plate photomultiplier tube (PMT) to detect neutron activity, with an optical fiber bundle connecting the two components.
  • It can accurately measure bang times for neutron yields above 10^7, with a timing precision of better than 60 picoseconds, and correlates the bang time with the start time of laser-generated x-ray pulses from 200 ps laser hits on gold targets.

Article Abstract

A neutron bang time (NBT) diagnostic system has been implemented on Shenguang-III prototype. The bang time diagnostic system is based on a sensitive fusion neutron detector, which consists of a plastic scintillator and a micro-channel plate photomultiplier tube (PMT). An optical fiber bundle is used to couple the scintillator and the PMT. The bang time system is able to measure bang time above a neutron yield of 10(7). Bang times and start time of laser were related by probing x-ray pulses produced by 200 ps laser irradiating golden targets. Timing accuracy of the NBT is better than 60 ps.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4870902DOI Listing

Publication Analysis

Top Keywords

bang time
20
diagnostic system
12
neutron bang
8
time diagnostic
8
shenguang-iii prototype
8
bang
6
time
6
note neutron
4
system
4
system shenguang-iii
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!