Quantification of halobetasol propionate and its impurities present in topical dosage forms by stability-indicating LC method.

J Chromatogr Sci

Analytical Research and Development, SAI Life Sciences Ltd., Pune 411 057, India.

Published: January 2015

A novel, sensitive, stability-indicating, gradient, reverse-phase high-performance liquid chromatographic method has been developed for quantitative determination of halobetasol propionate and its impurities in topical dosage forms. The chromatographic separation was achieved on a Phenomenex Synergi polar reverse phase, 250 × 4.6 mm, 4 µm column. Mobile phase A comprises a mixture of 0.01 M KH2PO4 buffer containing 0.2% 1-octane sulfonic acid sodium salt (pH 3.0), acetonitrile and methanol in the ratio 80:15:05 (v/v/v), respectively, and mobile phase B contains a mixture of 0.01 M KH2PO4 buffer containing 0.2% 1-octane sulfonic acid sodium salt (pH 3.0), acetonitrile and methanol in the ratio 20:70:10 (v/v/v), respectively. The flow rate is 0.8 mL min(-1). The column compartment temperature is set at 40°C and the detection wavelength is set at 240 nm. The resolutions between Halobetasol propionate and all the impurities are >2.0 for all pairs of compounds. The drug product was subjected to International Conference on Harmonization (ICH)-prescribed hydrolytic, oxidative, photolytic and thermal stress conditions. The method is validated as per the ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision, robustness and ruggedness.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmu029DOI Listing

Publication Analysis

Top Keywords

halobetasol propionate
12
propionate impurities
12
impurities topical
8
topical dosage
8
dosage forms
8
mobile phase
8
mixture 001
8
001 kh2po4
8
kh2po4 buffer
8
buffer 02%
8

Similar Publications

Concerns over the emergence of steroid hormones as pollutants in water have grown. Steroid hormone compounds present challenges in the simultaneous detection of total residual hormones owing to their analogous structures and diverse types. In this study, we established a rapid and high-throughput continuous online method based on solid phase extraction (SPE) coupled with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the simultaneous determination of 61 hormone components, including 48 glucocorticoids, 1 mineralocorticoid, 4 androgens, and 8 progesterones, in water.

View Article and Find Full Text PDF

Introduction: An expert panel of Canadian dermatologists was assembled to develop consensus statements regarding the current landscape of topical therapies for plaque psoriasis and the place in therapy of the recently approved fixed-dose combination halobetasol propionate (HP)/tazarotene (TAZ) lotion (HP/TAZ) in the treatment algorithm for plaque psoriasis.

Method: A modified nominal group technique, which combined both independent and group input from the expert panel, was used to develop the consensus statements. The expert panel completed surveys to elicit their independent views on the current landscape of topical therapies for plaque psoriasis in Canada.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!