Purpose: To evaluate fetal cerebral venous blood oxygenation, Yv, using principles of MR susceptometry.

Materials And Methods: A cohort of 19 pregnant subjects, with a mean gestational age of 31.6 ± 4.7 weeks were imaged using a modified susceptibility-weighted imaging (SWI) sequence. Data quality was first assessed for feasibility of oxygen saturation measurement, and data from five subjects (mean ± std gestational age of 33.7 ± 3.6 weeks) were then chosen for further quantitative analysis. SWI phase in the superior sagittal sinus was used to evaluate oxygen saturation using the principles of MR susceptometry. Systematic error in the measured Y(v) values was studied through simulations.

Results: Simulations showed that the systematic error in Yv depended upon the assumed angle of the vessel, θ, relative to the main magnetic field and the error in that vessel angle δθ. For the typical vessel angle of θ = 30° encountered in the fetal data analyzed, a δθ as large as ±20° led to an absolute error, δYv, of less than 11%. The measured mean oxygen saturation across the five fetuses was 66% ± 9.4%. This average cerebral venous blood oxygenation value is in close agreement with values in the published literature.

Conclusion: We have reported the first in vivo measurement of human fetal cerebral venous oxygen saturation using MRI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4007351PMC
http://dx.doi.org/10.1002/jmri.24245DOI Listing

Publication Analysis

Top Keywords

oxygen saturation
16
venous blood
12
blood oxygenation
12
cerebral venous
12
susceptibility-weighted imaging
8
fetal cerebral
8
gestational age
8
systematic error
8
vessel angle
8
measuring venous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!