A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative Evaluation of the Effects of Light Intensities and Curing Cycles of QTH, and LED Lights on Microleakage of Class V Composite Restorations. | LitMetric

Background: The purpose of this study was to evaluate the effects of light intensity and curing cycles of QTH and LED lights on the microleakage of Class V composite restorations.

Materials And Methods: Eighty freshly extracted human maxillary premolars were used for this study. Standardized Class V cavities were prepared and they were restored with microhybrid resin composite. According to the curing protocol, the teeth were then divided into 4 groups (n=20): QTH curing (standard and soft start modes), and LED (standard and soft start modes) irradiations. Microleakage was evaluated by immersion of the samples in 50% silver nitrate solution. The samples were then sectioned, evaluated under a stereomicroscope, and scored for microleakage.

Results: The results of the present in-vitro study showed mean dye leakage scores of 1.9, 1.2, 1.45 and 0.90 for Group I (QTH-Standard mode), Group II (QTH-Soft Start mode), Group III (LED-Standard mode) and Group IV (LED-Soft Start mode) respectively.

Conclusion: It was thus concluded that the soft start polymerization showed a highly significant difference as compared to the standard curing modes of QTH and LED lights, respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4003649PMC
http://dx.doi.org/10.7860/JCDR/2014/7463.4167DOI Listing

Publication Analysis

Top Keywords

qth led
12
led lights
12
soft start
12
mode group
12
effects light
8
curing cycles
8
cycles qth
8
lights microleakage
8
microleakage class
8
class composite
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!