Stable isotope-labeled internal standards (SIL-ISs) are often used when applying liquid chromatography-tandem mass spectrometry (LC-MS/MS) to analyze for legal and illegal drugs. ISs labeled with (13)C, (15)N, and (18)O are expected to behave more closely to their corresponding unlabeled analytes, compared with that of the more classically used (2)H-labeled ISs. This study has investigated the behavior of amphetamine, (2)H3-, (2)H5, (2)H6-, (2)H8-, (2)H11-, and (13)C6-labeled amphetamine, during sample preparation by liquid-liquid extraction and LC-MS/MS analyses. None or only minor differences in liquid-liquid extraction recoveries of amphetamine and the SIL-ISs were observed. The chromatographic resolution between amphetamine and the (2)H-labeled amphetamines increased with the number of (2)H-substitutes. For chromatographic studies we also included seven additional (13)C6-amphetamines and their analytes. All the (13)C6-labeled ISs were co-eluting with their analytes, both when a basic and when an acidic mobile phase were used. MS/MS analyses of amphetamine and its SIL-ISs showed that the ISs with the highest number of (2)H-substitutes required more energy for fragmentation in the collision cell compared with that of the ISs with a lower number. The findings, in this study, support those of previous studies, showing that (13)C-labeled ISs are superior to (2)H-labeled ISs, for analytical purposes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2014.04.020DOI Listing

Publication Analysis

Top Keywords

internal standards
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
2h-labeled iss
8
liquid-liquid extraction
8
amphetamine sil-iss
8
number 2h-substitutes
8
iss
7
amphetamine
5

Similar Publications

Background: Febrile illness in returned travelers presents a diagnostic challenge in non-endemic settings. Chat generative pretrained transformer (ChatGPT) has the potential to assist in medical tasks, yet its diagnostic performance in clinical settings has rarely been evaluated. We conducted a preliminary validation assessment of ChatGPT-4o's performance in the workup of fever in returning travelers.

View Article and Find Full Text PDF

Background: In longitudinal studies of older persons, complete ascertainment of mortality is needed to minimize potential biases. To ascertain mortality in the National Health and Aging Trends Study (NHATS), investigators are advised to use its Sensitive files, which include month and year of death on most decedents who had not dropped out of the study. Because losses to follow-up are not insubstantial, ascertainment of mortality is likely incomplete.

View Article and Find Full Text PDF

In coronary artery bypass grafting (CABG), the use of the left internal mammary artery (LIMA) is considered the gold standard. The conventional technique of using electrocautery for LIMA harvesting is associated with adverse events. In this study, we used a different technique that combined carbon dioxide with electrocautery to harvest LIMA and compared it with the conventional electrocautery method.

View Article and Find Full Text PDF

Background: No questionnaire is currently available for use in patients with shoulder pain in an Indonesian-speaking population. This study aimed to translate the Oxford Shoulder Score (OSS) into Indonesian and assess its validity and reliability for use in Indonesian-speaking patients with shoulder pain.

Methods: After a forward and backward translation procedure, the validity and reliability of the questionnaire were investigated.

View Article and Find Full Text PDF

Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.

Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!