For almost all injecting drug users (IDUs), the first site of injection is the arm. Years after injection, IDUs may shift to using other sites for intravenous (IV) access. Although injection to sites other than the arm is associated with higher risks, literature is limited regarding this behavior. We aimed to determine the prevalence and associated factors of using IV access points other than the arm among a national sample of IDUs in Iran. Data came from the National Drug Dependence Survey, 2007, which had enrolled 863 IDUs with at least one daily injection. Data on socio-demographics, pattern of drug use, and injection-related behaviors were entered into a logistic regression to determine predictors of injection to sites other than the arm. From all participants, 54.8% reported current injection sites in areas other than the arm. The other injection sites were the femoral venous sinus (17.0%), followed by the groin (14.5%) and neck (11.5%). Logistic regression revealed that living alone [odds ratio (OR) = 1.789, 95% confidence interval (CI) = 1.218-2.629], being Sunni (OR = 3.475, 95% CI = 1.775-6.801), having higher family income (OR = 1.002, 95% CI = 1.001-1.003), higher age at first drug use (OR = 1.039, 95% CI = 1.009-1.069), longer injection duration (OR = 1.071, 95% CI = 1.041-1.102), and more injection frequency (OR = 1.255, 95% CI = 1.072-1.471) were associated with higher likelihood of using injection sites other than the arm. Using sites other than the arm for IV injection is linked to socio-demographics, drug use data, and injection-related characteristics that can be used by policy makers. This information can be used for harm reduction planning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3985009PMC
http://dx.doi.org/10.3389/fpsyt.2014.00023DOI Listing

Publication Analysis

Top Keywords

injection sites
24
sites arm
20
injection
11
sites
8
arm
8
associated higher
8
logistic regression
8
arm injection
8
drug
6
95%
6

Similar Publications

Background: Central venous catheter placement has been associated with mechanical complications, some of which can be life-threatening. Recent studies have shown that simulation-based education on ultrasound-guided central venous catheter placement improves puncture success rates; however, its effect on reducing mechanical complications remains unclear. This observational study examined how outcome-based simulation training for ultrasound-guided central venous catheter placement affects the incidence of mechanical complications in a clinical setting.

View Article and Find Full Text PDF

Relationship between functional structures and horizontal connections in macaque inferior temporal cortex.

Sci Rep

January 2025

Department of Neurosurgery of the Second Affiliated Hospital, Interdisciplinary Institute of Neuroscience and Technology, School of Medicine, Zhejiang University, Hangzhou, China.

Horizontal connections in anterior inferior temporal cortex (ITC) are thought to play an important role in object recognition by integrating information across spatially separated functional columns, but their functional organization remains unclear. Using a combination of optical imaging, electrophysiological recording, and anatomical tracing, we investigated the relationship between stimulus-response maps and patterns of horizontal axon terminals in the macaque ITC. In contrast to the "like-to-like" connectivity observed in the early visual cortex, we found that horizontal axons in ITC do not preferentially connect sites with similar object selectivity.

View Article and Find Full Text PDF

Misfolding and aggregation of proteins into amyloidogenic assemblies are key features of several metabolic and neurodegenerative diseases. Human insulin has long been known to form amyloid fibrils under various conditions, which affects its bioavailability and function. Clinically, insulin aggregation at recurrent injection sites poses a challenge for diabetic patients who rely on insulin therapy.

View Article and Find Full Text PDF

Background: Entrapment neuropathies, marked by nerve compression at various anatomical sites, can be effectively managed using conservative approaches like injections. Dextrose 5 % water injection has emerged as a potential therapy by reducing inflammation and promoting tissue regeneration. We aimed to evaluate dextrose injection's efficacy in treating entrapment neuropathies in upper extremities.

View Article and Find Full Text PDF

Anaemia is a prevalent complication in patients with end-stage kidney disease (ESKD) undergoing haemodialysis. This study evaluates the accuracy of the Alio SmartPatch™, a non-invasive remote monitoring device, in measuring haemoglobin (Hb) and haematocrit (Hct) levels in haemodialysis patients by comparing its results with standard blood-based laboratory methods. The results from 116 patients across multiple sites in the USA and the Kingdom of Jordan show that SmartPatch measurements align closely with standard blood-based laboratory methods, meeting clinically acceptable limits of agreement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!