Background: A new approach of using photographs from smartphones for three-dimensional (3D) imaging was introduced besides the standard high quality 3D camera systems. In this work, we investigated different capture preferences and compared the accuracy of this 3D reconstruction method with manual tape measurement and an established commercial 3D camera system.

Methods: The facial region of one plastic mannequin head was labelled with 21 landmarks. A 3D reference model was captured with the Vectra 3D Imaging System®. In addition, 3D imaging was executed with the Autodesk 123d Catch® application using 16, 12, 9, 6 and 3 pictures from Apple® iPhone 4 s® and iPad® 3rd generation. The accuracy of 3D reconstruction was measured in 2 steps. First, 42 distance measurements from manual tape measurement and the 2 digital systems were compared. Second, the surface-to-surface deviation of different aesthetic units from the Vectra® reference model to Catch® generated models was analysed. For each 3D system the capturing and processing time was measured.

Results: The measurement showed no significant (p>0.05) difference between manual tape measurement and both digital distances from the Catch® application and Vectra®. Surface-to-surface deviation to the Vectra® reference model showed sufficient results for the 3D reconstruction of Catch® with 16, 12 and 9 picture sets. Use of 6 and 3 pictures resulted in large deviations. Lateral aesthetic units showed higher deviations than central units. Catch® needed 5 times longer to capture and compute 3D models (average 10 min vs. 2 min).

Conclusion: The Autodesk 123d Catch® computed models suggests good accuracy of the 3D reconstruction for a standard mannequin model, in comparison to manual tape measurement and the surface-to-surface analysis with a 3D reference model. However, the prolonged capture time with multiple pictures is prone to errors. Further studies are needed to investigate its application and quality in capturing volunteer models. Soon mobile applications may offer an alternative for plastic surgeons to today's cost intensive, stationary 3D camera systems.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0034-1371822DOI Listing

Publication Analysis

Top Keywords

manual tape
16
tape measurement
16
reference model
16
accuracy reconstruction
12
camera systems
8
autodesk 123d
8
123d catch®
8
catch® application
8
measurement digital
8
surface-to-surface deviation
8

Similar Publications

A novel method for assessing the shedding of fibre in forensic science: Investigating the effects of washing.

Forensic Sci Int

January 2025

Leverhulme Research Centre for Forensic Science, Department of Science and Engineering, University of Dundee, Dundee DD1 4HN, UK.

The evaluation of the shedding capacity of a garment is crucial in forensic analysis to understand fibre transfer mechanisms during contact activities. While adhesive tapes are commonly used, the lack of standardised pressure application -often done manually- poses a challenge. In addition, while previous studies have examined the effects of washing on fibre evidence, there is a notable absence in the literature regarding its impact on garment shedding capacity.

View Article and Find Full Text PDF

Testing is an important task within software development. To write test cases and integrate them into an automated test suite requires a significant amount of work. Given a set of requirements and specifications of a software, testing is needed to verify its correctness.

View Article and Find Full Text PDF

Objective: Smartphone applications (apps) with optical imaging capabilities are transforming the field of physical anthropometry; digital measurements of body size and shape in clinical settings are increasingly feasible. Currently available apps are usually designed around the capture of two-dimensional images that are then transformed with app software to three-dimensional (3D) avatars that can be used for digital anthropometry. The aim of the current study was to compare waist circumference (WC), hip circumference (HC), four other circumferences (right/left upper arm, thigh) and WC/HC evaluated with a novel high-precision 3D smartphone app to ground-truth measurements made with a flexible tape by a trained anthropometrist.

View Article and Find Full Text PDF

Background: Post-mastectomy lymphedema is a common complication following breast cancer surgery, characterized by the accumulation of lymphatic fluid, causing swelling, discomfort, and functional limitations in the affected arm. Traditional treatments for lymphedema include manual lymphatic drainage and compression garments, but their effectiveness is variable, and many patients do not achieve satisfactory outcomes. Emerging therapeutic modalities such as Low-Level Laser Therapy (LLLT), Kinesio Taping, and Endermology offer potential non-invasive treatment alternatives.

View Article and Find Full Text PDF

The impact of Kinesio Taping® on manual dexterity in Multiple Sclerosis: A double-blind, parallel-arm, pilot study.

J Bodyw Mov Ther

October 2024

Department of Geriatrics and Orthopaedics, Università Cattolica del Sacro Cuore, 00168, Rome, Italy; UOS Riabilitazione Post-Acuzie, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168, Rome, Italy. Electronic address:

Introduction: A range of signs and symptoms that often impair up-per extremity function characterizes Multiple Sclerosis (MS). People with MS may have impairments that make some activities of daily living difficult and reduce functional independence. A multidisciplinary rehabilitation approach, combined with pharmacological treatment, can be helpful in improving hand and upper limb function in people with Multiple Sclerosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!