Purpose: Conventional meshes for hernia repair and abdominal wall reinforcement are usually made from polypropylene, polyester or other synthetic plastic materials known to promote foreign body reactions and a state of chronic inflammation that may lead to long-term complications. A novel approach is to use long-term resorbable implants like TIGR(®) Matrix Surgical Mesh. Preclinical studies have shown that this mesh maintains mechanical integrity beyond the point in time where newly formed tissue is capable of carrying the abdominal loads.
Methods: This was a first-in-man, prospective, pilot study performed during 2009, at two sites in Sweden. Forty patients with primary inguinal hernias were enrolled for Lichtenstein repair using TIGR(®) Matrix Surgical Mesh. The primary endpoint was safety as assessed by monitoring the incidence of adverse events and serious adverse events (SAEs) both related and unrelated to the mesh. The secondary endpoint was pain or discomfort. Visual Analogue Scale (VAS) 0-10 and Inguinal Pain Questionnaire were used for scoring pain and discomfort. Included patients have been followed for 36 months using ultrasound in combination with clinical examination.
Results: All patients followed a normal early postoperative course. After 12 months no SAEs were reported. None of the patients with an isolated lateral inguinal hernia (LIH) had developed a recurrence but 4 (44 %) with medial and 4 (33 %) with combined hernias had recurred at 36-month follow-up. After 3-year follow-up none of the patients with LIH reported pain in the VAS-form and none of those patients could feel the sensation of a mesh in their groin. In the total study population 5 (16 %) patients experienced chronic pain in the form of mild sporadic pain and 3 (9.7 %) patients could feel the sensation of a mesh in their groin.
Conclusion: The use of a synthetic long-term resorbable mesh (TIGR(®) Matrix Surgical Mesh) in Lichtenstein repair was found to be safe, without recurrences, and promising regarding pain/discomfort at 3-year follow-up in patients with LIH. However, patients with medial and combined inguinal hernias had high recurrence rates.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4177566 | PMC |
http://dx.doi.org/10.1007/s10029-014-1249-1 | DOI Listing |
J Periodontal Res
January 2025
Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Aim: This study aimed to evaluate and compare the results of combination therapy involving bone grafting and two different resorbable collagen membranes in 1-, 2- and 3-wall infrabony defects.
Methods: A total of 174 patients with infrabony defects (≥ 7 mm periodontal probing depth) were randomized to receive deproteinized bovine bone mineral (DBBM) with either a native porcine non-crosslinked collagen membrane (N-CM, control, n = 87) or a novel porcine crosslinked collagen membrane (C-CM, test, n = 87). Clinical parameters, including periodontal probing depth (PPD), clinical attachment level (CAL), and gingival recession (GR), were recorded at baseline, 12 weeks, and 24 weeks.
Cureus
November 2024
Obstetrics and Gynecology, Kawasaki Medical School, Kurashiki, JPN.
Placenta accreta spectrum (PAS) is a life-threatening condition characterized by abnormal placental invasion of the myometrium and is often associated with uterine surgery. However, it can also occur in unscarred uteri, particularly during pregnancies using assisted reproductive technology (ART). Following a successful pregnancy via vitrified-warmed embryo transfer, a 33-year-old nulliparous woman with systemic lupus erythematosus and long-term steroid use presented with intra-abdominal hemorrhage due to placenta percreta and spontaneous uterine perforation at week 10 of gestation.
View Article and Find Full Text PDFSci Adv
December 2024
McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Drive NW, Calgary T2N 4Z6, Canada.
Mechanical unloading causes bone loss, but it remains unclear whether disuse-induced changes to bone microstructure are permanent or can be recovered upon reloading. We examined bone loss and recovery in 17 astronauts using time-lapsed high-resolution peripheral quantitative computed tomography and biochemical markers to determine whether disuse-induced changes are permanent. During 6 months in microgravity, resorption was threefold higher than formation.
View Article and Find Full Text PDFJ Long Term Eff Med Implants
December 2024
Universidad Europea de Madrid, Master of Oral Surgery and Advanced Implantology, Madrid, Spain, 28045.
The objective of the study was to compare the surgical vs. the nonsurgical techniques in the treatment of peri-implant diseases and to obtain a comprehensive analysis of the effects on BOP/probing depths when applying either the surgical technique vs. a nonsurgical technique.
View Article and Find Full Text PDF3D Print Med
December 2024
Department of Biomedical Engineering, Medical Additive Manufacturing Research Group (Swiss MAM), University of Basel, Allschwil, Switzerland.
The most common surgical procedure to manage the malunion of the bones is corrective osteotomy. The current gold standard for securing the bone segments after osteotomy is the use of titanium plates and allografts which have disadvantages such as possible allergic reaction, additional operations such as extraction of the graft from other sites and removal operation. The utilization of resorbable materials presents an opportunity to mitigate these drawbacks but has not yet been thoroughly researched in the literature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!