A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid and sensitive detection of melamine in milk with gold nanoparticles by Surface Enhanced Raman Scattering. | LitMetric

Rapid and sensitive detection of melamine in milk with gold nanoparticles by Surface Enhanced Raman Scattering.

Food Chem

Thermodynamic Division, Istituto Nazionale di Ricerca Metrologica, Strada delle Cacce, 91 10135 Torino, Italy.

Published: September 2014

A rapid and sensitive method to detect melamine in liquid milk based on Surface Enhanced Raman Scattering (SERS) spectroscopy is presented, exploiting the selective binding of gold nanoparticles (AuNPs) with this analyte. This interaction promotes the aggregation of the AuNPs inducing a huge enhancement of the melamine signals in the Raman spectrum due to the formation of SERS "hot spots". An external standard calibration method was employed for quantitative analysis and the method was validated for linearity, sensitivity, repeatability and recovery. A good linearity (R(2)=0.99) was found in the concentration range of 0.31-5.0 mg l(-1) in milk with a limit of detection of 0.17 mg l(-1). This method does not require a long extraction procedure (total analysis time can be lower than 30 min) and can be reliably used for melamine detection in milk matrix in accordance with the European law limits.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2014.03.013DOI Listing

Publication Analysis

Top Keywords

rapid sensitive
8
gold nanoparticles
8
surface enhanced
8
enhanced raman
8
raman scattering
8
sensitive detection
4
melamine
4
detection melamine
4
milk
4
melamine milk
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!