Detection of microorganisms by blood cultures (BCs) is essential in managing patients with bacteraemia. Rather than the number of punctures, the volume of blood drawn is considered paramount in efficient and reliable detection of microorganisms. We performed a 1-year prospective multicentre study in adult emergency departments of three French university hospitals comparing two methods for BCs: a unique blood culture (UBC) collecting a large volume of blood (40 mL) and the standard method of multiple blood cultures (MBC). The performances of both methods for bacterial contamination and efficient microbial detection were compared, each patient serving as his own control. Amongst the 2314 patients included, three hundred were positive for pathogens (n=245) or contaminants (n=55). Out of the 245 patients, 11 were positive for pathogens by UBC but negative by MBC and seven negative by UBC but positive by MBC (p 0.480). In the subgroup of 137 patients with only two BCs, UBC was superior to MBC (p 0.044). Seven and 17 patients had contaminated BCs by UBC and MBC only, respectively (p 0.062). Considering the sums of pathogens missed and contaminants, UBC significantly outperformed MBC (p 0.045). Considering the complete picture of cost savings, efficient detection of microorganisms and decrease in contaminations, UBC offers an interesting alternative to MBC.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1469-0691.12656DOI Listing

Publication Analysis

Top Keywords

detection microorganisms
12
unique blood
8
blood culture
8
emergency departments
8
prospective multicentre
8
multicentre study
8
blood cultures
8
volume blood
8
positive pathogens
8
bcs ubc
8

Similar Publications

Alpine wet meadows are known as NO sinks due to nitrogen (N) limitation. However, phosphate addition and N deposition can modulate this limitation, and little is known about their combinative effects on NO emission from the Qinghai-Tibet Plateau in wet meadows. This study used natural wet meadow as the control treatment (CK) and conducted experiments with N (CONH addition, N15), P (NaHPO addition, P15), and their combinations (CONH and NaHPO addition, N15P15) to investigate how N and P supplementation affected soil NO emissions in wet meadow of QTP.

View Article and Find Full Text PDF

This collaborative work by over 180 researchers from 40+ countries addresses the challenges posed by "phantom agents"-putative pathogenic agents named in literature without supporting data on their existence. Those agents remain on regulatory lists, creating barriers in trade and plant certification. Historically identified based solely on symptoms, these agents lack isolates or sequence data, making reliable detection or risk assessment impossible.

View Article and Find Full Text PDF

Microbial crosstalk with dermal immune system: A review on emerging analytical methods for macromolecular detection and therapeutics.

Int J Biol Macromol

December 2024

Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi 630 003, Tamil Nadu, India; Academy of Scientific & Innovative Research (AcSIR), Ghaziabad 201 002, India. Electronic address:

According to global health metrics, clinical symptoms such as cellulitis and pyoderma associated with skin diseases are a significant burden worldwide, affecting 2.2 million disability-adjusted life years in 2020. There is a strong correlation between the commensal bacteria and the host immune system.

View Article and Find Full Text PDF

A multirange paper-based analytical device for identifying low, moderate, and high P. aeruginosa bacterial loads in sputum samples.

Biosens Bioelectron

December 2024

Multidisciplinary Sepsis Group, Hospital Universitario Son Espases, Health Research Institute of Balearic Islands (IdISBa), Palma de Mallorca, Spain; CIBER de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III Madrid, Spain. Electronic address:

In this article we introduce a multirange analytical device that extends the dynamic range of nanoparticle-based immunoassays thanks to a multisensor design. Multirange devices contain low- and high-range sensors in the same analytical platform. The low-range sensor defines the limit of detection and quantifies low concentrated analytes, whereas the high-range sensor defines the upper limit of the dynamic range.

View Article and Find Full Text PDF

The Conference 2024 provides a platform to promote the development of an innovative scientific research ecosystem for microbiome and One Health. The four key components - Technology, Research (Biology), Academic journals, and Social media - form a synergistic ecosystem. Advanced technologies drive biological research, which generates novel insights that are disseminated through academic journals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!