Objectives: The purpose of this study was to determine the changes (if any) in the diameter and valve closure time of the lower limb veins in healthy young nulliparous women at different phases of the menstrual cycle.

Methods: Fifty-three young nulliparous women were asked to undergo clinical evaluations and duplex ultrasound examinations of both lower limb veins to monitor changes in the vein diameter and valve closure time at different phases of their menstrual cycles. The vein diameter on B-mode imaging and valve closure time on pulsed Doppler tracing were calculated at days 1 to 4, 14 to 16, and 25 to 28 of the menstrual cycle. Freidman and related samples Wilcoxon signed rank tests were used to determine time-related changes in venous function.

Results: The volunteers' mean age ± SD was 20.60 ± 1.90 years, and their mean body mass index was 23.90 ± 4.90 kg/m(2). There was a gradual increase in the vein diameter and valve closure time at the specified phases of the menstrual cycle. Friedman and related samples Wilcoxon signed rank tests for venous segment diameter and valve closure time changes between the different phases of the menstrual cycle were performed and showed statistical significance for each venous segment within each limb (P = .003-.025). Also, when adjusted for body mass index, statistical significance existed for the same venous segments in the same limbs (P =.001-.049). There was no statistical significance for the same venous segments at the same phase of the menstrual cycle between limbs (related samples Wilcoxon signed rank test: P =.079-.97).

Conclusions: During the menstrual cycle, the lower limb veins show an increase in their diameter and valve closure time. These changes are probably mediated by the female sex hormones.

Download full-text PDF

Source
http://dx.doi.org/10.7863/ultra.33.5.803DOI Listing

Publication Analysis

Top Keywords

valve closure
28
closure time
28
diameter valve
24
menstrual cycle
24
phases menstrual
16
lower limb
12
limb veins
12
vein diameter
12
samples wilcoxon
12
wilcoxon signed
12

Similar Publications

Diagnostic value of selected fetal echocardiographic parameters in the prenatally suspected bicuspid aortic valve.

Echo Res Pract

January 2025

Echocardiography Medical Center, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, 100029, China.

Objective: To explore the diagnostic value of crucial parameters of echocardiography for fetal bicuspid aortic valve (BAV) and improve diagnostic accuracy.

Methods: Fetuses with a prenatal suspected diagnosis of BAV were followed, and confirmed and misdiagnosed cases were obtained. Prenatal echocardiography was reviewed and analyzed.

View Article and Find Full Text PDF

BACKGROUND Terminal ileum (TI) anastomoses present challenges due to anatomical features and pressure from the ileocecal valve (ICV). The use of negative-pressure wound therapy (NPWT) is commonly used to treat chronic skin ulcers. Its use for temporary abdominal closure following anastomosis is controversial but has shown promise in patients with inflammatory or vascular disease.

View Article and Find Full Text PDF

Background: Vascular and bleeding complications remain a concern after transfemoral transcatheter aortic valve replacement (TAVR). The impact of the sheath type on these complications remains unclear.

Methods: The prospective MARVEL registry study analyzed enrolled 500 patients undergoing large-bore transfemoral procedures and arteriotomy closure with the MANTA vascular closure device from 10 hospitals in Europe and Canada.

View Article and Find Full Text PDF

Aortic annular rupture is a rare and usually fatal complication of TAVR. We report the case of a sub-annular aortic rupture contained in the right ventricle and percutaneously repaired. The procedure was complicated by new-onset severe tricuspid regurgitation related to tricuspid injury during wire externalization and immediately treated by transcatheter edge-to-edge repair.

View Article and Find Full Text PDF

In recent years, there has been a notable increase in the use of robotic technology in medical surgery, especially in heart surgery. Many advancements in surgery have been made possible by the development of these robotic devices, such as the da Vinci surgical system (Intuitive Surgical, Sunnyvale, California, United States). These advancements include improved ergonomics, three-dimensional (3D) imaging, and increased dexterity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!