Clinician perspectives on considering radiation exposure to patients when ordering imaging tests: a qualitative study.

BMJ Qual Saf

Division of General Internal Medicine, Department of Medicine, UCSF, San Francisco, California, USA.

Published: November 2014

Background And Objectives: Increased computer tomography (CT) scan use has contributed to a rise in medically-associated radiation exposure. The extent to which clinicians consider radiation exposure when ordering imaging tests is unknown. We examined (1) outpatient clinician attitudes towards considering radiation exposure when ordering CT scans; and (2) clinician reactions to displaying radiation exposure information for CT scans at clinician electronic order entry.

Methods: We conducted nine focus groups with primary care clinicians and subspecialty physicians (nephrology, pulmonary and neurology) (n=50) who deliver outpatient care across 12 hospital-based clinics and community health centres in an urban safety-net health system, which use a common electronic order entry system. We analysed focus group transcripts using an inductive framework to identify emergent themes and illustrative quotations.

Findings: Clinicians felt they had limited knowledge of the clinical implications of radiation exposure. Many believed clinically relevant information such as the increased risk of malignancy from CT scans would be useful to inform decision-making and patient-clinician discussions. Clinicians noted that patient vulnerability and long wait times for tests with less radiation exposure (such as MRI or ultrasound) often acted as barriers to minimise patient radiation exposure from CT scans. Clinicians suggested providing patients' cumulative radiation exposure or formal decision aids to improve the usefulness of the radiation exposure information.

Conclusions: Displaying clinically relevant radiation exposure information at order entry may improve clinician knowledge and inform patient-clinician discussions regarding risks and benefits of imaging. However, limited access to tests with lower radiation exposure in safety-net settings may trump efforts to minimise patient radiation exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bmjqs-2013-002773DOI Listing

Publication Analysis

Top Keywords

radiation exposure
52
radiation
13
exposure
13
considering radiation
8
ordering imaging
8
imaging tests
8
exposure ordering
8
scans clinician
8
exposure scans
8
electronic order
8

Similar Publications

Keratin/chitosan film promotes wound healing in rats with combined radiation-wound injury.

J Mater Sci Mater Med

January 2025

Department of Nuclear Medicine, Chongqing University Cancer Hospital, No. 181 HanYu St, Shapingba District, Chongqing, 400030, PR China.

Human hair keratin, a natural protein derived from human hair, has emerged prominently in the field of wound repair, showcasing its unique regenerative capabilities and extensive application potential. However, it is a challenge for the keratin to efficiently therapy the impaired wound healing, such as combined radiation-wound injury. Here, we report a keratin/chitosan (KRT/CS) film for skin repair of chronic wounds in in rats with combined radiation-wound injury.

View Article and Find Full Text PDF

The (PSS) experiment was part of the European Space Agency's mission and was conducted on the International Space Station from 2014 to 2016. The PSS experiment investigated the properties of montmorillonite clay as a protective shield against degradation of organic compounds that were exposed to elevated levels of ultraviolet (UV) radiation in space. Additionally, we examined the potential for montmorillonite to catalyze UV-induced breakdown of the amino acid alanine and its potential to trap the resulting photochemical byproducts within its interlayers.

View Article and Find Full Text PDF

Background: Radiation therapy (RT) treats primary and metastatic brain tumors, with about one million Americans surviving beyond six months post-treatment. However, up to 90% of survivors experience RT-induced cognitive impairment. Emerging evidence links cognitive decline to RT-induced endothelial dysfunction in brain microvessels, yet studies of endothelial injury remain limited.

View Article and Find Full Text PDF

Purpose: Mitoxantrone (MTX) is largely restricted in clinical usage due to its significant cardiotoxicity. Multiple studies have shown that an imbalance in the gut-heart axis plays an important role in the development of cardiovascular disease (CVD). We aim to explore the possible correlations between gut microbiota (GM) compositions and cardiometabolic (CM) disorder in MTX-triggered cardiotoxicity mice.

View Article and Find Full Text PDF

The quality of CT images obtained from hepatocellular carcinoma (HCC) patients is complex, affecting diagnostic accuracy, precision, and radiation dose assessment due to increased exposure risks. The study evaluated image quality qualitatively and quantitatively by comparing quality levels with an effective radiation dose to ensure acceptable quality accuracy. This study retrospectively reviewed 100 known HCC patients (Li-RADS-5) who underwent multidetector computed tomography (MDCT) multiphasic scans for follow-up of their health condition between January and October 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!