Characterization of an in-vacuum PILATUS 1M detector.

J Synchrotron Radiat

Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587 Berlin, Germany.

Published: May 2014

A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of the PTB at the electron storage ring BESSY II in Berlin, Germany. Owing to its windowless operation, the detector can be used in the entire photon energy range of the beamline from 10 keV down to 1.75 keV for small-angle X-ray scattering (SAXS) experiments and anomalous SAXS at absorption edges of light elements. The radiometric and geometric properties of the detector such as quantum efficiency, pixel pitch and module alignment have been determined with low uncertainties. The first grazing-incidence SAXS results demonstrate the superior resolution in momentum transfer achievable at low photon energies.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S160057751400294XDOI Listing

Publication Analysis

Top Keywords

pilatus detector
8
detector
5
characterization in-vacuum
4
in-vacuum pilatus
4
detector dedicated
4
dedicated in-vacuum
4
in-vacuum x-ray
4
x-ray detector
4
detector based
4
based hybrid
4

Similar Publications

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers.

Rev Sci Instrum

September 2024

Proto Manufacturing Inc., Taylor, Michigan 48180, USA.

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev.

View Article and Find Full Text PDF

MOSARIX: Multi-crystal spectrometer in the tender x-ray range at SOLEIL synchrotron.

Rev Sci Instrum

May 2024

Laboratoire de Chimie Physique-Matière et Rayonnement, CNRS, UMR 7614, Sorbonne Université, 4 Place Jussieu, 75252 Paris, France.

We have built and commissioned a novel standalone multi-crystal x-ray spectrometer (MOSARIX) in the von Hamos configuration based on highly annealed pyrolytic graphite crystals. The spectrometer is optimized for the energy range of 2-5 keV, but this range can be extended up to 20 keV by using higher reflection orders. With its nine crystals and a Pilatus detector, MOSARIX achieves exceptional detection efficiency with good resolving power (better than 4000), opening the door to study small cross section phenomena and perform fast in situ measurements.

View Article and Find Full Text PDF

In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination.

J Synchrotron Radiat

May 2023

X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA.

Flat-field calibration of X-ray area detectors is a challenge due to the inability to generate an X-ray flat-field at the selected photon energy the beamline operates at, which has a strong influence on the measurement behavior of the detector. A method is presented in which a simulated flat-field correction is calculated without flat-field measurements. Instead, a series of quick scattering measurements from an amorphous scatterer is used to calculate a flat-field response.

View Article and Find Full Text PDF

Spatial calibration and synthetic diagnostic of a multi-energy hard x-ray camera at WEST tokamak.

Rev Sci Instrum

October 2022

Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam-target emission of tungsten at the target due to fast electron losses interacting with the divertor plates.

View Article and Find Full Text PDF

Flexible positioning of a large area detector using an industrial robot.

J Synchrotron Radiat

July 2022

Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom.

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!