From the *Department of Pediatrics, Division of Emergency Medicine, Seattle Children's, University of Washington School of Medicine, Seattle, WA; †Department of Pediatrics, Division of Emergency Medicine, and ‡Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital of Chicago, Feinberg School of Medicine, Northwestern University, Chicago, IL.

Published: May 2014

Objective: The objective of this study was to describe fluoroscopy screen time (FST) for children undergoing contrast enema (CE) for suspected intussusception.

Methods: This is a single-center, retrospective cohort study of children younger than 7 years examined for intussusception by CE. We reviewed medical records for demographics, radiographic results, and FST. We used nonparametric descriptive statistical tests and calculated odds ratios (OR).

Results: The median FST for 457 included CEs was 116 seconds. The median FST for positive CEs (n = 194) was 138 seconds (95% confidence interval [CI], 126-152); for negative CEs (n = 250), 86 seconds (95% CI, 78-102); and for uncertain studies (n = 13), 138 seconds (95% CI, 89-208) (P < 0.01). There was no difference in median FST if symptoms were present 24 hours or less versus longer than 24 hours. There was no difference between contrast types. Median FST for successful reductions was 122 seconds (95% CI, 114-138). In cases of failed reductions, median FST for those undergoing surgery was 277 seconds (95% CI, 195-370) and 175 seconds (95% CI, 128-271) (P < 0.01) for those undergoing delayed repeat CE. The OR for receiving a repeat CE was 1.3 (95% CI, 1.1-1.4; P < 0.01) for every minute of FST. The OR for undergoing surgical reduction was 1.3 (95% CI, 1.2-1.5; P < 0.01) for every minute of FST and 3.7 (95% CI, 2.0-6.9; P < 0.01) for FST longer than 3 minutes.

Conclusions: Fluoroscopy screen time for the evaluation and diagnosis of intussusception is shorter than that previously described. When an initial screening ultrasound is not available or nondiagnostic and the suspicion is high, further evaluation with a CE may be warranted because the radiation exposure is likely lower than that previously reported.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PEC.0000000000000122DOI Listing

Publication Analysis

Top Keywords

seconds 95%
24
median fst
20
fluoroscopy screen
12
screen time
12
fst
10
95%
9
contrast enema
8
138 seconds
8
fst undergoing
8
001 minute
8

Similar Publications

COLOFIT: Development and Internal-External Validation of Models Using Age, Sex, Faecal Immunochemical and Blood Tests to Optimise Diagnosis of Colorectal Cancer in Symptomatic Patients.

Aliment Pharmacol Ther

January 2025

Gastrointestinal and Liver Theme, National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre (BRC), Nottingham University Hospitals NHS Trust and the University of Nottingham, School of Medicine, Queen's Medical Centre, Nottingham, UK.

Background: Colorectal cancer (CRC) is the third most common cancer in the United Kingdom and the second largest cause of cancer death.

Aim: To develop and validate a model using available information at the time of faecal immunochemical testing (FIT) in primary care to improve selection of symptomatic patients for CRC investigations.

Methods: We included all adults (≥ 18 years) referred to Nottingham University Hospitals NHS Trust between 2018 and 2022 with symptoms of suspected CRC who had a FIT.

View Article and Find Full Text PDF

Effects of double data extraction on errors in evidence synthesis: a crossover, multicenter, investigator-blinded, randomized controlled trial.

Postgrad Med J

January 2025

Proof of Concept Center, Eastern Hepatobiliary Surgery Hospital, Third Affiliated Hospital, Second Military Medical University, Naval Medical University, No. 255, Yangpu District, Shanghai, 200433, China.

Objectives: The objective was to investigate the role of double extraction in reducing data errors in evidence synthesis for pharmaceutical and non-pharmaceutical interventions.

Design: Crossover randomized controlled trial (RCT).

Setting: University and hospital with teaching programs in evidence-based medicine.

View Article and Find Full Text PDF

Background: Deutetrabenazine is a widely used drug for the treatment of tardive dyskinesia (TD), and post-marketing testing is important. There is a lack of real-world, large-sample safety studies of deutetrabenazine. In this study, a pharmacovigilance analysis of deutetrabenazine was performed based on the FDA Adverse Event Reporting System (FAERS) database to evaluate its relevant safety signals for clinical reference.

View Article and Find Full Text PDF

Background: Low-density lipoprotein cholesterol (LDL-C) has been determined as an established risk factor for acute ischemic stroke (AIS). Despite the recommendation for in-hospital initiation of high-intensity statin therapy in AIS patients, achieving the desired target LDL-C levels remains challenging. Evolocumab, a highly effective and quickly acting agent for reducing LDL-C levels, has yet to undergo extensively exploration in the acute phase of AIS.

View Article and Find Full Text PDF

Objective: To explore the potential correlation between gallstone disease (GSD) prevalence and circadian syndrome (CircS).

Methods: The cross-sectional research utilized data spanning 2017 to March 2020, sourced from the National Health and Nutrition Examination Survey (NHANES). The GSD data were collected via questionnaires, with appropriate sample weights applied to ensure the study population was representative.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!