Percutaneous pulmonary balloon valvuloplasty as a procedure of choice in adults has been established since the last three decades. Even though the complications are rare, they are scarcely reported in the literature. We report such a case in an adult female patient of severe pulmonary valular stenosis in whom, entrapped catheter across the fossa ovalis was noted in chest x-ray and echocardiogram following unsuccessful percutaneous pulmonary balloon valvuloplasty. Our case emphasizes this rare complication and its successful surgical outcome.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3987453 | PMC |
BMC Cardiovasc Disord
January 2025
Department of Cardiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.
Guidewire entrapment (GE) is a rare complication that warrants complex interventions or surgical procedures. Here, we report the removal of an entrapped guidewire using excimer laser coronary angioplasty (ELCA) in a case of chronic total occlusion (CTO). Plaque tissue trapped with the guidewire was also removed.
View Article and Find Full Text PDFJ Invasive Cardiol
January 2025
Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania.
Objectives: The Wolverine cutting balloon (CB) (Boston Scientific) is a specialized balloon catheter with microsurgical blades that is used for balloon-resistant lesions. The Manufacturer and User Facility Device Experience (MAUDE) database serves as a repository for reports of medical device complications. The aim of this study was to analyze complications associated with CB use during percutaneous coronary intervention in real-world contemporary practice.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
February 2025
Department of Vascular Surgery, Sir Charles Gairdner Hospital, Perth, Australia.
A 2-day-old neonate was referred to the vascular surgery service owing to concerns of limb perfusion after entrapment of a microcatheter in the middle cerebral artery. The catheter was inserted via the umbilical artery to treat a vein of Galen arteriovenous malformation. This catheter inadvertently became entrapped owing to device failure, was cut at the insertion site, and left in situ for 3 months.
View Article and Find Full Text PDFInt Urol Nephrol
January 2025
Department of Surgery, University of Missouri-Kansas City School of Medicine, 2301 Holmes Street, Kansas City, MO, 64108, USA.
J Pregnancy
December 2024
Department of Preventive and Social Medicine, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.
Preinduction cervical ripening in previous caesarean pregnancy is limited to intracervical Foley catheter. This study is aimed at finding the vaginal birth rates, improvement of Bishop score, and safety of osmotic dilator (Dilapan-S) among women with previous caesarean pregnancy. We conducted this single-group clinical study after the approval of the institute ethics committee, clinical trial registration, and obtaining informed consent.