The effect of endoscopic sheaths on visualization in distal chip and fiberoptic laryngoscopy.

Eur Arch Otorhinolaryngol

Department of Otorhinolaryngology, Head and Neck Surgery, University of Groningen, University Medical Center Groningen, P.O. Box 30001, 9700 RB, Groningen, The Netherlands,

Published: October 2014

Endoscopic sheaths covering the laryngoscope are advised to prevent cross contamination, but might hamper visualization as the most important tool in the diagnostic approach of laryngeal disease. We evaluated whether endoscopic sheaths change image quality and diagnostic accuracy of flexible distal chip laryngoscopy (DCL) and flexible fiberoptic laryngoscopy (FOL). Twelve healthy volunteers underwent a flexible laryngoscopy using a distal chip and a fiberoptic laryngoscope with and without endoscopic sheaths, and in this way 48 images were collected. To determine diagnostic accuracy, the 48 images were mixed with images of 40 patients. All images were randomly shown to four experts in the field of laryngology and head and neck oncology. Observers were asked to validate image quality, choose a diagnosis, and express their confidence level of that diagnosis. Image quality was validated better in DCL as compared to FOL (p < 0.05) both with or without endoscopic sheaths. Endoscopic sheaths worsened image quality in DCL (p < 0.05) but not in FOL. No differences were observed between DCL and FOL with or without endoscopic sheaths in diagnostic accuracy (79-89%). Confidence levels (7.7-8.1) were comparable in DCL and FOL and not influenced by endoscopic sheaths. Image quality in DCL is superior to FOL, but significantly hampered by the use of endoscopic sheaths. In FOL the image quality is already low and not further diminished by endoscopic sheaths.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00405-014-3058-7DOI Listing

Publication Analysis

Top Keywords

endoscopic sheaths
40
image quality
24
distal chip
12
diagnostic accuracy
12
endoscopic
10
sheaths
9
chip fiberoptic
8
fiberoptic laryngoscopy
8
quality dcl
8
dcl fol
8

Similar Publications

We describe a patient with severe Arnold Chiari Malformation and syringomyelia who underwent gynecological laparoscopy in an emergency context; no brain imaging was available. We here report the successful use of optic nerve sheath diameter (ONSD) and middle cerebral artery (MCA) velocity measurements as surrogate monitoring for cerebral blood flow and intracranial pressure, respectively. MCA velocity was low when assessed after peritoneal insufflation and ONSD increased to 6.

View Article and Find Full Text PDF

Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).

Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.

View Article and Find Full Text PDF

Adenomatous Polyposis Coli (APC) is a tumor suppressor gene expressed throughout the body. APC mutations increase the risk of malignancy and are often characterized by syndromes that encompass a spectrum of neoplastic manifestations, such as familial adenomatous polyposis (FAP). We present a rare case of palatal peripheral nerve sheath tumor in the context of APC gene mutation.

View Article and Find Full Text PDF

Case: An 18-year-old woman presented with shoulder pain that had persisted for a year. The magnetic resonance imaging showed a solitary lesion in the subacromial bursa (SAB). Arthroscopy revealed an ovoid mass connected to the bursal wall with thin synovial tissue that was excised en bloc arthroscopically.

View Article and Find Full Text PDF

In intrasheath peroneal tendon subluxation, the peroneal tendons subluxate on each other within the retrofibular peroneal tendon sheath. Two subtypes can be distinguished: type A, in which the tendons are normal, and type B, in which the peroneus brevis tendon has an associated longitudinal split and the peroneus longus tendon subluxates through this tendon split. The purpose of this technical note is to describe the details of endoscopic retrofibular groove deepening for management of type A intrasheath peroneal tendon subluxation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!