Background: The chimney technique has been developed for the treatment of complex aortic aneurysms. We analyzed the midterm to long-term outcomes of this approach from a single-center experience.
Methods: From October 2008 to July 2016, 58 patients underwent endovascular aortic aneurysm repair using the chimney technique. Indications for treatment were thoracic aortic aneurysm (TAA) (N.=11), thoracoabdominal aortic aneurysm (TAAA) (N.=2), pararenal aortic aneurysm (PAAA) (N.=15), aortoiliac/isolated hypogastric artery aneurysm (N.=25), type I endoleak after previous TEVAR/EVAR (N.=4), proximal pseudoaneurysm after AAA open repair (N.=1). Elective (82.8%) and emergent (17.2%) procedures were included.
Results: The immediate technical success was 100%. Single, double and triple chimneys were performed in 46, 10, and two patients, respectively. Overall, 61 target vessels (three left common carotid arteries, eight left subclavian arteries, three celiac trunks, three superior mesenteric arteries, 19 renal arteries and 25 hypogastric arteries) were involved. Postoperative mortality was 0. No neurologic complications were registered. Primary patency rate of the chimney stent/stent graft was 98.3%. Low-flow type I endoleak was observed in four patients (6.9%). Postoperative chimney graft re-intervention rate was 1.7%. The median follow-up was 32±20 months (range 3-96 months). Overall estimated survival at 12, 50, and 80 months was 100%, 89% and 44%, respectively. Estimated freedom from endoleak at 1, 12, 24, and 36 months was 96.5%, 95%, 95%, and 93%, respectively. One hypogastric artery stent-graft occluded at the 3rd month of follow-up. No reintervention was performed.
Conclusions: Our experience with the chimney technique for aortic aneurysms from the aortic arch to the iliac axis shows promising and durable mid- and long-term results. Endograft oversizing, associated with the chimney graft diameter and length choice remain fundamental to reduce the risk of the most frequent procedure complications: type I endoleak and CG occlusion. The wider use of this technique should be justified in patients considered at high risk for open repair and/or not suitable for the custom-made branched/fenestrated endografts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.23736/S0021-9509.16.08179-9 | DOI Listing |
Int J Surg
December 2024
Department of Surgery, University of New Mexico Health Sciences, Albuquerque, NM, USA.
Abdominal aortic aneurysms (AAAs) are a significant vascular pathology in older adults, often asymptomatic but with high mortality upon rupture. Despite advancements in diagnostic imaging and surgical interventions, AAAs remain a public health concern. This research letter analyzed CDC WONDER data on AAA-related deaths (ICD-10 I71.
View Article and Find Full Text PDFIntroduction: Thoracic aortic aneurysms (TAA) are a significant health concern, with the true prevalence likely underestimated due to undiagnosed cases. Outcomes in TAA are influenced by factors like age, sex, and comorbidities such as hypertension. This study examines mortality trends and disparities associated with TAA in US adults.
View Article and Find Full Text PDFPerfusion
January 2025
Department of Cardiac and Vascular Surgery, Heart and Vascular Center Segeberger Kliniken, Bad Segeberg, Germany.
We report the case of a 72-year-old male patient who presented with a progressive aortic arch aneurysm. To reduce surgical trauma, we planned the procedure using an upper partial sternotomy with continuous cardiac perfusion and moderate hypothermia. Two vents were inserted to provide sufficient relief to the heart during perfusion.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai 20032, China.
J Endovasc Ther
January 2025
Vascular Unit, Department of Surgery, Mater Dei Hospital, Msida, Malta.
Purpose: The use of surgeon-modified fenestrated endograft to treat a bleeding complication in the common iliac artery.
Technique: An Endurant limb graft was modified on back table in theater after planning the fenestration using a semi-automated centerline. The Endurant stent was planned to land flush at the aortic bifurcation.