Background: The important point in safely performing laparoscopic hepatectomy (LH) is to control bleeding. The aims of this study were: (i) to assess the bleeding reduction effect by occlusion of the hepatic artery in LH; and (ii) to evaluate the risk of carbon dioxide (CO2 ) gas embolism (GE) in the case of high pneumoperitoneum (PP).

Methods: Nine piglets underwent laparoscopic left medial lobe and left lateral lobe resection, receiving either occlusion of the hepatic artery (hepatic artery clamping group: HACG, n = 9) or no occlusion (hepatic artery declamping group: HADCG, n = 9) using a PP of 15 mmHg. In addition, we observed changes in hemodynamics induced by PP. The state of GE was observed using transesophageal echocardiography (TEE) during LH (n = 8). GE was graded as grade 0 (none), grade 1 (minor), and grade 2 (major).

Results: The HACG had significantly less bleeding compared to the HADCG (P < 0.01). During LH, four animals showed grade 1 (37.5%) and one animal showed grade 2 (12.5%) GE at 15 mmHg. At 20 mmHg, all animals showed grade 2 (100%) GE.

Conclusion: The occlusion of the hepatic artery in LH reduces blood loss. The control of bleeding from the hepatic vein is feasible with a high PP, but there is a possibility of GE.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jhbp.103DOI Listing

Publication Analysis

Top Keywords

hepatic artery
24
occlusion hepatic
20
risk carbon
8
carbon dioxide
8
gas embolism
8
laparoscopic hepatectomy
8
control bleeding
8
animals grade
8
hepatic
7
artery
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!