Automated detection of the arterial input function using normalized cut clustering to determine cerebral perfusion by dynamic susceptibility contrast-magnetic resonance imaging.

J Magn Reson Imaging

Sino-Dutch Biomedical and Information Engineering School of Northeastern University, Shenyang, Liaoning, China; Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, Liaoning, China.

Published: April 2015

Purpose: To propose a new clustering method for the automatic detection of arterial input function (AIF) with high accuracy in dynamic susceptibility contrast-magnetic resonance imaging (DSC-MRI).

Materials And Methods: A novel method for automatically determining the AIF was proposed to facilitate the analysis of MR perfusion, which relied on normalized cut (Ncut) clustering. Its performance was compared with those of two other previously reported clustering methods: k-means and fuzzy c-means (FCM) techniques, in terms of the detection accuracy and computational time. Both simulated perfusion data and data collected from 42 healthy human subjects were applied to investigate the feasibility of the proposed approach.

Results: In the simulation study, the partial volume effect (PVE) level, peak value (PV), time to peak (TTP), full width at half maximum (FWHM), area under AIF curve (AUC), root mean square error (RMSE) between the estimated AIF and true AIF, and M value given by [PV/(FWHM×TTP)] were 45.45, 4.2737, 29.92, 6.4563, 76.4836, 0.0519, and 0.0221 for Ncut-based AIF, 96.45, 3.8385, 31.74, 7.5133, 75.7364, 0.3295, and 0.0161 for FCM-based AIF, 91.18, 3.8990, 31.73, 7.4544, 76.0476, 0.3128, and 0.0165 for k-means-based AIF, 0, 4.4592, 29.51, 6.2016, 76.8669, 0, and 0.0244 for true AIF. In the clinical study, the mean PV, TTP, FWHM, AUC, M, error between estimated AIF and manual AIF were 1.7395, 30.95, 5.5923, 19.1081, 0.0397, and 0.4406 for Ncut-based AIF, 1.3629, 31.31, 6.8616, 17.9992, 0.0123, and 0.0846 for k-means-based AIF, 1.2101, 31.61, 7.1729, 16.6238, 0.0102, and 0.1016 for FCM-based AIF. The differences in PV, M, FWHM, and error reached a significant level (P = 0.032, 0.010, 0.003, and 0.002, respectively) between Ncut and k-means methods as well as between Ncut and FCM methods (P = 0.013, 0.008, 0.007, and 0.009, respectively). There was no significant difference in TTP between Ncut and each of the other two methods (P = 0.173 and 0.097, respectively). For AUC, a significant difference was found between Ncut and FCM algorithms (P = 0.025), but not between Ncut and k-means methods (P = 0.138). The mean execution time was 0.4406 for the Ncut method, 0.2649 for the k-means method, and 0.1371 for the FCM method, and the differences were significant both between Ncut and k-means methods (P = 0.002) and between Ncut and FCM methods (P = 0.004).

Conclusion: Ncut clustering yield AIFs more in line with the expected AIF, and might be preferred to FCM and k-means clustering methods sensitive to randomly selected initial centers.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.24642DOI Listing

Publication Analysis

Top Keywords

aif
15
ncut k-means
12
k-means methods
12
ncut fcm
12
ncut
10
methods
9
detection arterial
8
arterial input
8
input function
8
normalized cut
8

Similar Publications

Recent studies have suggested that sVEGFR3 is involved in cardiac diseases by regulating lymphangiogenesis; however, results are inconsistent. The aim of this study was to investigate the function and mechanism of sVEGFR3 in myocardial ischemia/reperfusion injury (MI/RI). sVEGFR3 effects were evaluated in vivo in mice subjected to MI/RI, and in vitro using HL-1 cells exposed to oxygen-glucose deprivation/reperfusion.

View Article and Find Full Text PDF

Synchronous vibrations, which are caused by periodic excitations, can have a severe impact on the service life of impellers. Blade Tip Timing (BTT) is a promising technique for monitoring synchronous vibrations due to its non-intrusive nature and ability to monitor all blades at once. BTT generally employs a Once-per-Revolution (OPR) sensor that is mounted on the shaft for blade identification and deflection calculation.

View Article and Find Full Text PDF

Experimental Study on Deep-Drawing Dies Made of Pre-Stressed UHPC.

Materials (Basel)

January 2025

Chair of Metal Forming and Casting, Technical University of Munich, Walther-Meissner-Strasse 4, 85748 Garching, Germany.

Deep drawing is a cost-efficient way of producing sheet metal parts in high production volumes. Prototypes and very small series are expensive due to the cost of steel-forming tools. Ultra-high-performance concrete (UHPC) tools offer a cheap and fast alternative to conventional steel-forming tools.

View Article and Find Full Text PDF

Background/objectives: Early postmortem mitochondrial function and apoptotic activation affect meat quality development. Nicotinamide riboside (NR) supplementation to pigs prior to harvest can improve pork color stability, but its mechanism remains unclear. This study aimed to evaluate the impact of NR supplementation on early postmortem mitochondrial functionality and apoptosis.

View Article and Find Full Text PDF

Nutrition plays a crucial role in human and planetary health, as prevailing nutritional patterns significantly contribute to the global non-communicable disease pandemic. Moreover, the global food system is inextricably linked to planetary health deterioration. The relevance of nutrition for individual and planetary health is insufficiently addressed in German medical schools.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!