Purposes: There is a small minority of patients with occlusive carotid artery disease, who are at high-risk for general anesthesia because of their intolerance to carotid flow blockage, even if only for seconds, without neurologic deficit. Even <30 s of temporary clamping of the carotid arteries to deploy a shunt may prove eventful in this patient group. We define safe carotid endarterectomy after the insertion of a novel shunt that we made from simple medical equipment in this patient population.
Methods: Among 65 patients who underwent carotid endarterectomy between March 2010 and December 2012, 5 (7.7 %; 3 men and 2 women; age range 56-77 years) could not tolerate carotid clamping. We used an alternative carotid shunt, made by us from simple equipment in our clinic, during surgery for these patients.
Results: Two patients had bilateral lesions and the remainder had unilateral disease. The degree of stenosis ranged from 70 to 95 %. Temporary carotid clamping resulted in neurologic events, such as loss of consciousness in all and tremor in one, in <10 s (range, from immediately to 8 s after clamping). Full neurologic function was regained 15-30 s after releasing the clamps. All of the patients tolerated the procedures well with the support of our novel shunt. Shunt flow was adequate in all patients and no neurologic deterioration occurred after carotid clamping. The mean carotid clamp time was 28.11 ± 14.19 min. There was no mortality and all patients were followed up for a mean period of 9.3 ± 3.6 months, uneventfully.
Conclusions: An alternative, simple shunt, which is easily constructed in the operating room or clinic, using an angiocatheter, a three-way stopcock, and a serum line can provide adequate cerebral flow and permit safe carotid endarterectomy for those rare patients with carotid artery stenosis, who cannot tolerate even seconds of carotid occlusion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00595-014-0896-2 | DOI Listing |
J Am Heart Assoc
January 2025
Department of Neurosurgery, Center of Pituitary Tumor, Ruijin Hospital Shanghai Jiao Tong University School of Medicine Shanghai China.
Background: Carotid endarterectomy (CEA) is widely used to treat carotid artery stenosis (CAS). However, the effects of CEA on unilateral CAS-induced cognitive impairment and the underlying mechanism remain poorly understood.
Methods And Results: Thirteen patients diagnosed with unilateral severe CAS underwent pre- and post-CEA assessments, including fluoro-2-deoxy-d-glucose positron emission tomography/magnetic resonance imaging, cognitive assessments, and routine blood tests before and after CEA.
Cureus
December 2024
Department of Cardiology, Geetanjali Medical College and Hospital, Udaipur, IND.
Background Carotid artery stenting is a well-established alternative treatment to carotid endarterectomy for carotid artery stenosis for preventing stroke. This study assessed the procedural and clinical outcomes in patients undergoing carotid artery stenting in a tertiary care center in India. Methods A total of 39 patients underwent carotid artery stenting from January 2022 to December 2023, with different embolic protection devices and carotid stents.
View Article and Find Full Text PDFAnn Ital Chir
January 2025
Institute of Central Nervous System Vascular Injury and Repair, Jining Medical Science Research Institute, The First People's Hospital of Jining, 272000 Jining, Shandong, China.
Aim: This study aims to report a rare case of an embolization protection device (EPD) entrapment during Carotid Artery Stent (CAS) and to discuss the management strategy, including open surgery and concurrent carotid endarterectomy (CEA).
Case Presentation: A 71-year-old female presented with left limb weakness and unclear speech following CAS. Imaging revealed a new cerebral infarction and right internal carotid artery stenosis.
JACC Cardiovasc Interv
December 2024
Department for Angiology, Brandenburg Medical School Theodor Fontane, Campus Clinic Brandenburg, Center for Internal Medicine I, Berlin, Germany; Department of Angiology, Sankt-Gertrauden-Krankenhaus, Berlin, Germany.
Background: Several randomized clinical trials have shown that the composite endpoint of death, stroke, and myocardial infarction (MI) is equivalent between carotid artery stenting and carotid endarterectomy. However, the risk of minor stroke has been consistently higher with carotid artery stenting.
Objectives: The authors sought to evaluate the safety and effectiveness of a novel carotid stent system comprised of a stent, an adjustable integrated embolic filter and a postdilation balloon, in patients at elevated risk for adverse events from carotid endarterectomy.
J Clin Med
December 2024
Collegium Medicum, WSB University, 41-300 Dabrowa Gornicza, Poland.
Eversion carotid endarterectomy (CEA) in awake patients is performed using cervical plexus blocks (CPBs) with or without carotid artery sheath infiltration (CASI) under ultrasound guidance. Although adequacy of anesthesia (AoA) guidance monitors nociception/antinociception balance, its impact on intraoperative analgesia quality and perioperative outcomes in awake CEA remains unexplored. Existing literature lacks evidence on whether AoA-guided anesthesia enhances clinical outcomes over standard techniques.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!