Proper femoral component rotation is crucial in successful total knee arthroplasty. Rotation using anatomic landmarks has traditionally referenced the transepicondylar axis (TEA), Whiteside's Line (WSL), or posterior condylar axis (PCA). TEA is thought to best approximate the flexion-axis of the knee, however WSL or PCA are common surrogates in the operating room. This study evaluated 560 knees using MRI-based planning software to assess the relationship of WSL and PCA to the TEA and determine if the relationships were influenced by pre-operative coronal deformity. Results showed the WSL-TEA relationship has more variability than PCA-TEA and that the PCA is more internally rotated in females and valgus knees. Axis options and historical assumptions about axis relationships may need to be reassessed as imaging technology advances.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2014.02.033DOI Listing

Publication Analysis

Top Keywords

femoral component
8
component rotation
8
total knee
8
knee arthroplasty
8
pca tea
8
wsl pca
8
rotation total
4
arthroplasty mri-based
4
mri-based evaluation
4
evaluation options
4

Similar Publications

Polyetheretherketone (PEEK) is a high-performance polymer material for developing varying orthopedic, spine, cranial, maxillofacial, and dental implants. Despite their commendable mechanical properties and biocompatibility, the major limitation of PEEK implants is their low affinity to osseointegrate with the neighboring bone. Over the last two decades, several efforts have been made to incorporate bioactive components such as bioceramic particles in PEEK to enhance its osseointegration capacity.

View Article and Find Full Text PDF

In functionally aligned total knee arthroplasty, femoral component rotation follows the transepicondylar axis to achieve flexion balance.

Knee Surg Sports Traumatol Arthrosc

January 2025

Clinical Research Department, Sydney Knee Specialists, Kogarah, New South Wales, Australia.

Purpose: In functionally aligned (FA) total knee arthroplasty (TKA), femoral component rotation (FCR) is personalised to optimise flexion gap balance. As axial malalignment has been attributed to patellofemoral complications, this study assessed FA FCR in relation to the surgical transepicondylar axis (TEA) and early implant survivorship.

Methods: We analysed 446 robotic-assisted primary TKAs in 393 patients using FA with preresection gap balancing.

View Article and Find Full Text PDF

Mid-term Clinical and Radiographic Outcomes of the Actis Total Hip System: A Retrospective Study.

Cureus

January 2025

Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, JPN.

Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years.

View Article and Find Full Text PDF

Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.

Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study.

View Article and Find Full Text PDF

Anterior cruciate ligament reconstruction aims to improve knee stability and range of motion. The AperFix system consists of polymer components, and fixed-loop fixation is an established endoscopic technique. Our aim in this study was to compare the long-term clinical and radiological results of AperFix and fixed-loop fixation and to prove that the long-term results of the AperFix fixation method are at least as good as those of the fixed loop device.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?