We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator's identification of landmarks to establish the image synchronization.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carrev.2014.03.008DOI Listing

Publication Analysis

Top Keywords

coronary angiography
8
intravascular ultrasound
8
optical coherence
8
coherence tomography
8
method real-time
4
real-time co-registration
4
co-registration coronary
4
angiography intravascular
4
ultrasound optical
4
tomography clinically
4

Similar Publications

Background: Coronary artery dominance is determined by the coronary artery emitting the posterior descending artery. In the left dominant system, a greater proportion of coronary flow enters the left coronary artery, potentially influencing calcified plaque development in the left anterior descending artery (LAD).

Methods: This retrospective single-center cohort study analyzed patients who underwent computed tomography angiography from September 2006 to December 2022 at Harbor-UCLA in Los Angeles, California.

View Article and Find Full Text PDF

Three-Dimensional CT for Preprocedural Planning of PCI for Ostial Right Coronary Artery Lesions: A Randomized Controlled Pilot Trial.

Circ Cardiovasc Interv

January 2025

Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (D.M.F.v.d.B., E.M.P., E.W., D.C., E.M., B.F., M.V., J.D., K.A.).

Background: Geographic stent-ostium mismatch is an important predictor of target lesion failure after percutaneous coronary intervention of an aorto-ostial right coronary artery lesion. Optimal visualization of the aorto-ostial plane is crucial for precise stent implantation at the level of the ostium. This study investigates whether preprocedural 3-dimensional computed tomography (3DCT), with determination of the optimal viewing angle, would allow for more precise stent implantation and reduce procedure time, contrast, and radiation dose.

View Article and Find Full Text PDF

Fibromuscular dysplasia (FMD) is a non-atherosclerotic, non-inflammatory vascular disease of medium-sized arteries that causes abnormal cellular growth in arterial walls and most commonly affects young to middle-aged women (20-50 years of age). While FMD often involves the renal arteries, it can affect any arterial bed. FMD has a characteristic angiographic appearance of a "string of beads.

View Article and Find Full Text PDF

Artificial intelligence-based quantitative coronary angiography (AI-QCA) was introduced to address manual QCA's limitations in reproducibility and correction process. The present study aimed to assess the performance of an updated AI-QCA solution (MPXA-2000) in lesion detection and quantification using manual QCA as the reference standard, and to demonstrate its superiority over visual estimation. This multi-center retrospective study analyzed 1,076 coronary angiography images obtained from 420 patients, comparing AI-QCA and visual estimation against manual QCA as the reference standard.

View Article and Find Full Text PDF

Background: Coronary sinus (CS) lead placement in persistent left superior vena cava (PLSVC) cases is challenging because of the poor backup force of the guiding catheter within the enlarged CS. Active fixation Quadripolar leads (Attain Stability™ Quad 4798, Medtronic) can expand choice to CS branches with limited access; however, no cases of anchoring to the main body of the CS have been published to date.

Case Summary: We describe a case of cardiac resynchronization therapy pacemaker upgrade in a 79-year-old female who developed pacing-induced cardiomyopathy after pacemaker implantation via the right superior vena cava (SVC) for atrioventricular block eight years ago wherein PLSVC was revealed during the procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!