Electromagnetic navigational bronchoscopy-guided fiducial markers for lung stereotactic body radiation therapy: analysis of safety, feasibility, and interfraction stability.

J Bronchology Interv Pulmonol

*Department of Radiation Medicine †Division of Pulmonary and Critical Care Medicine, Oregon Health and Science University ‡Pulmonary and Critical Care Medicine, Department of Veterans Affairs Medical Center, Portland, OR.

Published: April 2014

Background: Embolization coils as fiducial markers for pulmonary stereotactic body radiation therapy (SBRT) are perceived to be the optimal marker type, given their ability to conform and anchor within the small airways. The aim of our study was to assess retention, placement, migration, feasibility, and safety of electromagnetic navigational bronchoscopy (ENB)-guided embolization coil markers throughout courses of SBRT.

Methods: Thirty-one patients with 34 nodules underwent ENB-guided fiducial placement of several 4 mm fibered platinum embolization coils before SBRT. Patient and nodule positioning was confirmed with daily pretreatment cone-beam computed tomography (CBCT). Fiducial positional characteristics were analyzed utilizing radiation treatment-planning software comparing the simulation CT with daily CBCTs.

Results: Of 105 fiducials placed, 103 were identifiable on simulation CT (retention rate: 98.1%). Incidence of asymptomatic pneumothoraces was 6%. One patient experienced hemoptysis requiring hospitalization. Eighty-six percent of fiducials were placed within 1 cm of the nodule, with 52% of fiducials placed directly on the nodule surface. Throughout a 5-fraction SBRT course, fiducial displacement was <7, 5, and 2 mm in 98%, 96%, and 67% of pretreatment CBCTs.

Conclusions: ENB placement of embolization coils as fiducials for lung SBRT image guidance is associated with a low rate of iatrogenic pneumothoraces, and resulted in reliable placement of the fiducials in close proximity to the lung nodule. Embolization coils retained their relative position to the nodule throughout the course of SBRT, and provide an excellent alternative to linear gold seeds.

Download full-text PDF

Source
http://dx.doi.org/10.1097/LBR.0000000000000065DOI Listing

Publication Analysis

Top Keywords

electromagnetic navigational
8
fiducial markers
8
stereotactic body
8
body radiation
8
radiation therapy
8
embolization coils
8
fiducial
5
navigational bronchoscopy-guided
4
bronchoscopy-guided fiducial
4
markers lung
4

Similar Publications

High-Definition, Video-Rate Triple-Channel NIR-II Imaging Using Shadowless Lamp Excitation and Illumination.

ACS Nano

January 2025

State Key Laboratory of Extreme Photonics and Instrumentations, Centre for Optical and Electromagnetic Research, College of Optical Science and Engineering, International Research Center for Advanced Photonics, Zhejiang University, Hangzhou 310058, China.

Multichannel imaging in the second near-infrared (NIR-II) window offers vital and comprehensive information for complex surgical environments, yet a simple, high-quality, video-rate multichannel imaging method with low safety risk remains to be proposed. Centered at the superior NIR-IIx window of 1400-1500 nm, triple-channel imaging coordinated with 1000-1100 and 1700-1880 nm (NIR-IIc) achieves exceptional clarity and an impressive signal-to-crosstalk ratio as high as 22.10.

View Article and Find Full Text PDF

Magneto-responsiveness in living organisms, exemplified by migratory birds navigating vast distances, offers inspiration for soft robots and human-computer interfaces. However, achieving both high magneto-responsiveness and resilient mechanical properties in synthetic materials has been challenging. Here, we develop magneto-iono-elastomers (MINEs), combining exceptional magnetization [2.

View Article and Find Full Text PDF

Background: Metastatic retroperitoneal lymph node dissection (LND) for nodal recurrence is applied for a variety of cancers, such as urological, gynaecological and rectal cancer. Precise localisation and resection of these lymph nodes (LNs) during surgery can be challenging, especially after previous radiotherapy or surgery. The objective of this study was to assess the added value of surgical navigation for targeted LND in the retroperitoneum.

View Article and Find Full Text PDF

Peripheral pulmonary lesion: novel approaches in endoscopic guidance systems and a state-of-the-art review.

Monaldi Arch Chest Dis

December 2024

Respiratory Disease Unit, Department of Cardiac Thoracic and Vascular Sciences, Ospedale dell'Angelo, Venice.

Diagnosis of peripheral pulmonary lesion (PPL) is the most challenging field in bronchoscopy and interventional pulmonology, which concerns early lung cancer diagnosis. Despite novel techniques and new approaches to the periphery of the lung, almost 25% of PPLs remain undiagnosed. Bronchoscopy with guide systems, virtual and/or electromagnetic navigation, robotic bronchoscopy, and transparenchymal nodule approaches tend to provide a higher percentage of reaching the lesion, but the diagnostic yield rarely exceeds 75%, regardless of the instruments used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!