Whole brain, high resolution multiband spin-echo EPI fMRI at 7 T: a comparison with gradient-echo EPI using a color-word Stroop task.

Neuroimage

Radboud University Nijmegen, Donders Institute for Brain, Cognition and Behaviour, Donders Centre for Cognitive Neuroimaging, Trigon 204, P.O. Box 9101, NL-6500 HB Nijmegen, The Netherlands; Erwin L. Hahn Institute for Magnetic Resonance Imaging, UNESCO-Weltkulturerbe Zollverein, Leitstand Kokerei Zollverein, Arendahls Wiese 199, D-45141 Essen, Germany; MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, NL-7500 AE Enschede, The Netherlands.

Published: August 2014

A whole brain, multiband spin-echo (SE) echo planar imaging (EPI) sequence employing a high spatial (1.5 mm isotropic) and temporal (TR of 2 s) resolution was implemented at 7 T. Its overall performance (tSNR, sensitivity and CNR) was assessed and compared to a geometrically matched gradient-echo (GE) EPI multiband sequence (TR of 1.4 s) using a color-word Stroop task. PINS RF pulses were used for refocusing to reduce RF amplitude requirements and SAR, summed and phase-optimized standard pulses were used for excitation enabling a transverse or oblique slice orientation. The distortions were minimized with the use of parallel imaging in the phase encoding direction and a post-acquisition distortion correction. In general, GE-EPI shows higher efficiency and higher CNR in most brain areas except in some parts of the visual cortex and superior frontal pole at both the group and individual-subject levels. Gradient-echo EPI was able to detect robust activation near the air/tissue interfaces such as the orbito-frontal and subcortical regions due to reduced intra-voxel dephasing because of the thin slices used and high in-plane resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2014.04.011DOI Listing

Publication Analysis

Top Keywords

gradient-echo epi
12
multiband spin-echo
8
color-word stroop
8
stroop task
8
epi
5
brain high
4
high resolution
4
resolution multiband
4
spin-echo epi
4
epi fmri
4

Similar Publications

Background: Diagnostically adequate contrast and spatial resolution in brain MRI require prolonged scan times, leading to motion artifacts and image degradation in awake children. Rapid multi-parametric techniques can produce diagnostic images in awake children, which could help to avoid the need for sedation.

Objective: To evaluate the utility of a rapid echo-planar imaging (EPI)-based multi-inversion spin and gradient echo (MI-SAGE) technique for generating multi-parametric quantitative brain maps and synthetic contrast images in awake pediatric participants.

View Article and Find Full Text PDF

Purpose: This study leverages the echo planar time-resolved imaging (EPTI) concept in MR fingerprinting (MRF) framework for a new time-resolved MRF (TRMRF) approach, and explores its capability for fast simultaneous quantification of multiple MR parameters including T, T, T*, proton density, off resonance, and B .

Methods: The proposed TRMRF method uses the concept of EPTI to track the signal change along the EPI echo train for T* weighting with a k-t Poisson-based sampling order designed for acquisition. A two-dimensional decomposition algorithm was designed for the image reconstruction, enabling fast and precise subspace modeling.

View Article and Find Full Text PDF

Background: To investigate the artifact sizes of four common breast clip-markers on a standard breast magnetic resonance imaging (MRI) protocol in an in vitro phantom model.

Methods: Using 1.5-T and 3-T whole-body scanners with an 18-channel breast coil, artifact dimensions of four breast biopsy markers in an agarose-gel phantom were measured by two readers on images obtained with the following sequences: T2-weighted fast spin-echo short inversion time fat-suppressed inversion-recovery with magnitude reconstruction (T2-TIRM); T1-weighted spoiled gradient-echo with fat suppression (T1_FL3D), routinely used for dynamic contrast-enhanced imaging; diffusion-weighted imaging (DWI), including a readout segmented echo-planar imaging (RESOLVE-DWI) and echo-planar imaging sequence (EPI-DWI).

View Article and Find Full Text PDF

Purpose: To develop a 3D distortion-free reduced-FOV diffusion-prepared gradient-echo sequence and demonstrate its application in vivo for diffusion imaging of the spinal cord in healthy volunteers.

Methods: A 3D multi-shot reduced-FOV diffusion-prepared gradient-echo acquisition is achieved using a slice-selective tip-down pulse in the phase-encoding direction in the diffusion preparation, combined with magnitude stabilizers, centric k-space encoding, and 2D phase navigators to correct for intershot phase errors. The accuracy of the ADC values obtained using the proposed approach was evaluated in a diffusion phantom and compared to the tabulated reference ADC values and to the ADC values obtained using a standard spin echo diffusion-weighted single-shot EPI sequence (DW-SS-EPI).

View Article and Find Full Text PDF

Purposes: To enhance the functional capability of MRI, this study aims to develop a novel MR elastography (MRE) sequence that achieves rapid acquisition without distortion artifacts.

Methods: A displacement-encoded stimulated echo (DENSE) with multiphase acquisition scheme was used to capture wave images. A center-out golden-angle stack-of-stars sampling pattern was introduced for improved SNR and data incoherence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!