A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A method to relate StarTrack(®) measurements to R50 variations in clinical linacs. | LitMetric

A method to relate StarTrack(®) measurements to R50 variations in clinical linacs.

Phys Med

Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada, Spain.

Published: November 2014

The relation between the data recorded with any device for the daily checking of the behavior of a clinical linac and the reference magnitudes to be monitored may be unknown. An experimental method relating the energy stability of the electron beam measured with StarTrack(®) to the R50 beam quality index is proposed. The bending magnet current is varied producing a change in the exit energy window and, therefore, a modification of the R50 value. For different values of this current, the output data of StarTrack(®) and the R50, obtained from depth doses measured in a water phantom are determined. A linear fit between both sets of data allows the identification of the StarTrack(®) output that provides the best way to obtain the quality index R50, for each beam nominal energy. Using these fits, an historical datum series is used to analyze the method proposed in the daily quality control. The ouput data of the StarTrack(®) and the R50 values show a good linear correlation. It is possible to establish a methodology that allows the monitoring of R50 by direct use of the daily quality control data measured with StarTrack(®). A method to monitor R50 in the daily quality control using the StarTrack(®) device has been developed. The method may be applied to similar devices in which the statistical control variable does not show a linear behavior with R50.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2014.03.007DOI Listing

Publication Analysis

Top Keywords

startrack® r50
12
daily quality
12
quality control
12
r50
9
measured startrack®
8
r50 beam
8
r50 values
8
data startrack®
8
startrack®
7
method
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!