This study investigates the degradation performance of three Fe-based materials in a growing rat skeleton over a period of 1 year. Pins of pure Fe and two Fe-based alloys (Fe-10 Mn-1Pd and Fe-21 Mn-0.7C-1Pd, in wt.%) were implanted transcortically into the femur of 38 Sprague-Dawley rats and inspected after 4, 12, 24 and 52 weeks. The assessment was performed by ex vivo microfocus computed tomography, weight-loss determination, surface analysis of the explanted pins and histological examination. The materials investigated showed signs of degradation; however, the degradation proceeded rather slowly and no significant differences between the materials were detected. We discuss these unexpected findings on the basis of fundamental considerations regarding iron corrosion. Dense layers of degradation products were formed on the implants' surfaces, and act as barriers against oxygen transport. For the degradation of iron, however, the presence of oxygen is an indispensable prerequisite. Its availability is generally a critical factor in bony tissue and rather limited there, i.e. in the vicinity of our implants. Because of the relatively slow degradation of both pure Fe and the Fe-based alloys, their suitability for bulk temporary implants such as those in osteosynthesis applications appears questionable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2014.04.007DOI Listing

Publication Analysis

Top Keywords

fe-based alloys
12
pure fe-based
8
degradation
6
biodegradable fe-based
4
alloys osteosynthesis
4
osteosynthesis outcome
4
outcome vivo
4
vivo study
4
study weeks
4
weeks study
4

Similar Publications

Article Synopsis
  • CRAFT is a fusion technology facility in China focused on developing and validating fusion technology through methods like neutral beam injection.
  • A new negative ion based neutral beam injector is being created with a beam energy of 400 keV, utilizing a core snubber for surge suppression in its power supply system.
  • The design of the core snubber involves careful consideration of transmission line characteristics, and initial testing shows it effectively suppresses peak ignition current and oscillation.
View Article and Find Full Text PDF

Degradation behavior of austenite, ferrite, and martensite present in biodegradable Fe-based alloys in three protein-rich pseudo-physiological solutions.

Bioact Mater

November 2024

Laboratory for Biomaterials and Bioengineering, Canada Research Chair I in Biomaterials and Bioengineering for the Innovation in Surgery, Department of Min-Met-Materials Engineering, Research Center of CHU de Quebec, Division of Regenerative Medicine, Laval University, Quebec City, Canada.

This study investigates the degradation behavior of three distinct Fe-based alloys immersed in three pseudo-physiological solutions. These alloys, which have varied Mn and C contents, include a commercially available Fe-0.15C alloy, namely Fe-C, and two newly developed alloys, that is Fe-5Mn-0.

View Article and Find Full Text PDF

Synergetic degradation of PFOS by HALT conditions enhanced by Fe-based amorphous alloys.

J Hazard Mater

December 2024

State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China.

Global concern over per- and polyfluoroalkyl substances (PFASs), especially perfluorooctane sulfonate (PFOS), disposal prompts the search for effective degradation methods. Subcritical water hydrothermal treatment shows promise but suffers from unclear degradation pathways, hindering engineering application design due to unknown intermediate products. This study introduces Fe-based amorphous alloy to enhance the subcritical water hydrothermal degradation of PFOS, achieving a degradation rate of approximately 85 % under optimized conditions of 325 °C and 1 M sodium bicarbonate (NaHCO₃), compared to 56 % without the alloy.

View Article and Find Full Text PDF

This study examined the surface-grinding-induced microstructural modifications and corrosion attacks in a penetrating form of a high-Mn-low-Cr casting steel slab under humid environments. Various experimental and analytical findings from field-emission scanning electron microscopy, electron backscatter diffraction, transmission electron microscopy, and electrochemical analyses revealed that the abrasive grinding process led to the formation of a surface deformed region, comprising a recrystallized fine grain layer and multiple streamlines. Corrosion initially occurs preferentially along the boundary areas where Cr(Mn)C particles are precipitated.

View Article and Find Full Text PDF

This review aims to comprehensively and systematically analyze the anodic oxidation process to form nanostructured oxide films on the surface of the most technologically relevant Fe-based alloys and steels. A special emphasis is put on detailed analysis of the mechanisms of the anodic formation of Fe-based nanostructured materials. The effect of anodizing parameters including the type of Fe-alloy, electrolyte composition, potential/current regimes, as well as various post-treatment procedures (including annealing treatment) on the growth, morphology, composition, and properties of the resulting oxide films is discussed in detail.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!