The convenience of a computed tomography (CT) scanner in the emergency department (ED) may impact utilization rates. Our primary aim was to determine the rate of utilization before and after the placement of an ED CT scanner. Secondary aims were to determine the rate of utilization by anatomic region and during a 5-month period when the ED scanner was unavailable. We performed an electronic chart review of our ED with an annual census of 70,000 patients. We identified all patients over the age of 21 who had a CT scan performed from January 2008 to October 2010. Predetermined data elements were extracted by trained, hypothesis-blinded abstractors. Comparisons overall and within scan subtype were performed using seasonal matching. We found a CT utilization rate of 114 per 1,000 patient visits before and 139 per 1,000 patient visits after the placement of a CT scanner in the ED (p<0.0001). Linear regression analysis found a line with a slope of β=0.114 (95 % CI=0.107-0.121) and an R2 of 0.508. CT rates increased in the following regions: head CTs by 14 per 1,000 visits (p<0.0001); neck CTs by 3 per 1,000 visits (p<0.0001); abdomen/pelvis CTs by 4 per 1,000 visits (p=0.0015); "other" CTs by 2 per 1,000 visits (p<0.0001). Increased rates of chest and facial CTs approached significance with p values of 0.05. During the 5-month downtime, utilization remained unchanged at 141 per 1,000 visits (p=0.38). Overall CT utilization increased after the placement of a scanner in the ED. Most subtypes of scan increased. Utilization was unchanged during a period of ED scanner unavailability, suggesting that increased utilization may be difficult to reverse.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10140-014-1217-1 | DOI Listing |
Med Phys
January 2025
Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Stockholm, Sweden.
Background: Modern reconstruction algorithms for computed tomography (CT) can exhibit nonlinear properties, including non-stationarity of noise and contrast dependence of both noise and spatial resolution. Model observers have been recommended as a tool for the task-based assessment of image quality (Samei E et al., Med Phys.
View Article and Find Full Text PDFRadiography (Lond)
January 2025
UniSA Allied Health & Human Performance, University of South Australia, Adelaide, SA 5001, Australia.
Introduction: Radiographers support the multidisciplinary team by facilitating medical imaging within the operating theatre environment. This project aimed to enhance student readiness for clinical competency in operative theatre imaging by implementing an authentic C-arm simulator for students to use prior to attending clinical placement.
Methods: This study followed a pre-post, quantitative study design.
Imaging Sci Dent
December 2024
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy.
Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).
Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.
Pain Physician
December 2024
Department of Pain Management, West China Hospital/West China Tianfu Hospital, Sichuan University, Chengdu, Sichuan Province, China.
Stereotact Funct Neurosurg
December 2024
Introduction Cerebellar deep brain stimulation (DBS) is gaining traction as a potential treatment for movement disorders and stroke and there is renewed interest in the cerebellum as a target for neuromodulation. Despite the safety and accuracy of frame-based approaches to the posterior fossa, unconventional stereotactic frame placement may be necessary to allow for low posterior fossa trajectories. Current literature lacks a comprehensive protocol detailing inverted frame placement and targeting.