Computed tomography utilization rates after the placement of a scanner in an emergency department: a single-center experience.

Emerg Radiol

Department of Emergency Medicine, Harbor-UCLA Medical Center, David Geffen School of Medicine UCLA, Box 21, 1000, W Carson St. Torrance, Los Angeles, CA, 90509-2910, USA,

Published: October 2014

The convenience of a computed tomography (CT) scanner in the emergency department (ED) may impact utilization rates. Our primary aim was to determine the rate of utilization before and after the placement of an ED CT scanner. Secondary aims were to determine the rate of utilization by anatomic region and during a 5-month period when the ED scanner was unavailable. We performed an electronic chart review of our ED with an annual census of 70,000 patients. We identified all patients over the age of 21 who had a CT scan performed from January 2008 to October 2010. Predetermined data elements were extracted by trained, hypothesis-blinded abstractors. Comparisons overall and within scan subtype were performed using seasonal matching. We found a CT utilization rate of 114 per 1,000 patient visits before and 139 per 1,000 patient visits after the placement of a CT scanner in the ED (p<0.0001). Linear regression analysis found a line with a slope of β=0.114 (95 % CI=0.107-0.121) and an R2 of 0.508. CT rates increased in the following regions: head CTs by 14 per 1,000 visits (p<0.0001); neck CTs by 3 per 1,000 visits (p<0.0001); abdomen/pelvis CTs by 4 per 1,000 visits (p=0.0015); "other" CTs by 2 per 1,000 visits (p<0.0001). Increased rates of chest and facial CTs approached significance with p values of 0.05. During the 5-month downtime, utilization remained unchanged at 141 per 1,000 visits (p=0.38). Overall CT utilization increased after the placement of a scanner in the ED. Most subtypes of scan increased. Utilization was unchanged during a period of ED scanner unavailability, suggesting that increased utilization may be difficult to reverse.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10140-014-1217-1DOI Listing

Publication Analysis

Top Keywords

placement scanner
12
computed tomography
8
utilization rates
8
scanner emergency
8
emergency department
8
determine rate
8
rate utilization
8
1000 patient
8
patient visits
8
utilization
5

Similar Publications

Background: Modern reconstruction algorithms for computed tomography (CT) can exhibit nonlinear properties, including non-stationarity of noise and contrast dependence of both noise and spatial resolution. Model observers have been recommended as a tool for the task-based assessment of image quality (Samei E et al., Med Phys.

View Article and Find Full Text PDF

Enriching surgical theatre competence through computer-based simulation.

Radiography (Lond)

January 2025

UniSA Allied Health & Human Performance, University of South Australia, Adelaide, SA 5001, Australia.

Introduction: Radiographers support the multidisciplinary team by facilitating medical imaging within the operating theatre environment. This project aimed to enhance student readiness for clinical competency in operative theatre imaging by implementing an authentic C-arm simulator for students to use prior to attending clinical placement.

Methods: This study followed a pre-post, quantitative study design.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).

Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.

View Article and Find Full Text PDF

Efficacy of Higher-Voltage Long-Duration Pulsed Radiofrequency for Spinal Zoster-Associated Pain: A Randomized Controlled Trial.

Pain Physician

December 2024

Department of Pain Management, West China Hospital/West China Tianfu Hospital, Sichuan University, Chengdu, Sichuan Province, China.

Article Synopsis
  • The study evaluates the safety and effectiveness of a higher-voltage long-duration pulsed radiofrequency (HL-PRF) treatment for managing zoster-associated pain (ZAP) compared to standard treatment.
  • Patients in Group A received gradually increased voltage up to 100 V, while Group B maintained a steady 65 V throughout.
  • Results focused on pain levels, emotional well-being, and quality of life over 12 weeks, with an aim to address high recurrence rates associated with the existing methods.
View Article and Find Full Text PDF

Introduction Cerebellar deep brain stimulation (DBS) is gaining traction as a potential treatment for movement disorders and stroke and there is renewed interest in the cerebellum as a target for neuromodulation. Despite the safety and accuracy of frame-based approaches to the posterior fossa, unconventional stereotactic frame placement may be necessary to allow for low posterior fossa trajectories. Current literature lacks a comprehensive protocol detailing inverted frame placement and targeting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!