Background: Pacemaker (PM) interrogation requires correct manufacturer identification. However, an unidentified PM is a frequent occurrence, requiring time-consuming steps to identify the device.
Objective: The purpose of this study was to develop and validate a novel algorithm for PM manufacturer identification, using the ECG response to magnet application.
Methods: Data on the magnet responses of all recent PM models (≤15 years) from the 5 major manufacturers were collected. An algorithm based on the ECG response to magnet application to identify the PM manufacturer was subsequently developed. Patients undergoing ECG during magnet application in various clinical situations were prospectively recruited in 7 centers. The algorithm was applied in the analysis of every ECG by a cardiologist blinded to PM information. A second blinded cardiologist analyzed a sample of randomly selected ECGs in order to assess the reproducibility of the results.
Results: A total of 250 ECGs were analyzed during magnet application. The algorithm led to the correct single manufacturer choice in 242 ECGs (96.8%), whereas 7 (2.8%) could only be narrowed to either 1 of 2 manufacturer possibilities. Only 2 (0.4%) incorrect manufacturer identifications occurred. The algorithm identified Medtronic and Sorin Group PMs with 100% sensitivity and specificity, Biotronik PMs with 100% sensitivity and 99.5% specificity, and St. Jude and Boston Scientific PMs with 92% sensitivity and 100% specificity. The results were reproducible between the 2 blinded cardiologists with 92% concordant findings.
Conclusion: Unknown PM manufacturers can be accurately identified by analyzing the ECG magnet response using this newly developed algorithm.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hrthm.2014.04.011 | DOI Listing |
Cardiol Rev
January 2025
Departments of Cardiology and Medicine, New York Medical College and Westchester Medical Center, Valhalla, NY.
Right ventricular myocardial infarction (RVMI) is a significant and distinct form of acute myocardial infarction associated with considerable morbidity and mortality. It occurs most commonly due to proximal right coronary artery obstruction, often in conjunction with inferior myocardial infarction. RVMI poses unique diagnostic and therapeutic challenges due to the anatomical and functional differences between the right and left ventricles.
View Article and Find Full Text PDFBMJ Case Rep
January 2025
ARHC/Stroke Service, Naas General Hospital, Naas, Kildare, Ireland.
A woman in her early 60s presented with multiple transient neurological symptoms over the course of 20 months, including transient loss of power to her right lower limb. Initial workup with CT brain scan, carotid dopplers and ECG revealed no abnormality; however, MRI of the brain suggested recent ischaemic events in separate cortical territories. Subsequent transoesophageal echocardiogram revealed a large mobile mass histologically confirmed to be an atrial myxoma.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Child and Adolescent Center, Hospital CUF Descobertas, R. Mário Botas S/N, 1998-018 Lisboa, Portugal.
Background: While viruses remain the leading cause of infectious myocarditis, improved diagnostic methods have highlighted the role of bacteria as a possible cause. We report two cases of myocarditis as a complication of infection.
Case Summaries: Patient A, a 17-year-old Caucasian male with a history of asthma, presented to the emergency department (ED) after experiencing fever and nausea for four days, followed by 1 day of diarrhoea and chest discomfort.
BMJ Case Rep
January 2025
Cardiology, AIIMS, New Delhi, India
A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.
View Article and Find Full Text PDFJ Cardiovasc Magn Reson
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
Purpose: To investigate image quality and agreement of derived cardiac function parameters in a novel joint image reconstruction and segmentation approach based on disentangled representation learning, enabling real-time cardiac cine imaging during free-breathing.
Methods: A multi-tasking neural network architecture, incorporating disentangled representation learning, was trained using simulated examinations based on data from a public repository along with MR scans specifically acquired for model development. An exploratory feasibility study evaluated the method on undersampled real-time acquisitions using an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!