A system incorporating automated 3-D ultrasound and digital X-ray tomosynthesis is being developed for improved breast lesion detection and characterization. The goal of this work is to develop and test candidates for a dual-modality mesh compression paddle. A Computerized Imaging Reference Systems (Norfork, VA, USA) ultrasound phantom with tilted low-contrast cylindrical objects was used. Polyester mesh fabrics (1- and 2-mm spacing), a high-density polyethylene filament grid (Dyneema, DSM Dyneema, Stanley, NC, USA) and a solid polymethylpentene (TPX; Mitsui Plastics, Inc., White Plains, NY) paddle were compared with no overlying structures using a GE Logic 9 with M12L transducer. A viscous gel provided coupling. The phantom was scanned 10 times over 9 cm for each configuration. Image volumes were analyzed for signal strength, contrast and contrast-to-noise ratio. X-ray tests confirmed X-ray transparency for all materials. By all measures, both mesh fabrics outperformed TPX and Dyneema, and there were essentially no differences between 2-mm mesh and unobstructed configurations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2013.03.014DOI Listing

Publication Analysis

Top Keywords

mesh compression
8
mesh fabrics
8
mesh
5
acoustic performance
4
performance mesh
4
compression paddles
4
paddles multimodality
4
multimodality breast
4
breast imaging
4
imaging system
4

Similar Publications

Industrial and construction wastes make up about half of all world wastes. In order to reduce their negative impact on the environment, it is possible to use part of them for concrete production. Using experimental-statistical modeling techniques, the combined effect of brick powder, recycling sand, and alkaline activator on fresh and hardened properties of self-compacting concrete for the production of textile-reinforced concrete was investigated.

View Article and Find Full Text PDF

On the Properties of New Polyurethane Fast-Curing Polymer Materials.

Materials (Basel)

December 2024

State Key Laboratory of Explosion & Impact and Disaster Prevention & Mitigation, Army Engineering University of PLA, Nanjing 210007, China.

A sequences of unconfined compressive strength tests and flexural tests were conducted in this study to evaluate the curing performance of a new type of polyurethane sand fast-curing polymer material. The mechanical properties of the material were investigated under different curing temperatures (-10 °C to 60 °C), particle sizes (10-15 mesh, 60-80 mesh, 100-120 mesh, and 325 mesh), and material proportions (20% to 60%). Additionally, SEM analysis was employed to further reveal the reinforcement mechanism.

View Article and Find Full Text PDF

Background: Fibrous dysplasia (FD) is often difficult for skull base surgeons to address. FD arises due to the abnormal proliferation of fibroblasts, ultimately resulting in immature osseous tissue replacing normal cancellous bone. When the skull base is involved, it can result in cranial nerve compression.

View Article and Find Full Text PDF

Impact of thrombus composition on virtual thrombectomy procedures using human clot analogues mechanical data.

J Mech Behav Biomed Mater

January 2025

Department of Chemistry, Materials and Chemical Engineering 'Giulio Natta', Politecnico di Milano, Italy.

Endovascular thrombectomy (EVT) aims at restoring blood flow in case of acute ischemic stroke by removing the thrombus occluding a large cerebral artery. During the procedure with stent-retriever, the thrombus is captured within the device, which is then retrieved, subjecting the thrombus to several forces, potentially leading to its fragmentation. In silico studies, along with mechanical characterisation of thrombi, can enhance our understanding of the EVT, helping the development of new devices and interventional strategies.

View Article and Find Full Text PDF

Background: Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.

Objective: This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!