The left ventricular myocardium plays a key role in the entire circulation system and an automatic delineation of the myocardium is a prerequisite for most of the subsequent functional analysis. In this paper, we present a complete system for an automatic segmentation of the left ventricular myocardium from cardiac computed tomography (CT) images using the shape information from images to be segmented. The system follows a coarse-to-fine strategy by first localizing the left ventricle and then deforming the myocardial surfaces of the left ventricle to refine the segmentation. In particular, the blood pool of a CT image is extracted and represented as a triangulated surface. Then, the left ventricle is localized as a salient component on this surface using geometric and anatomical characteristics. After that, the myocardial surfaces are initialized from the localization result and evolved by applying forces from the image intensities with a constraint based on the initial myocardial surface locations. The proposed framework has been validated on 34-human and 12-pig CT images, and the robustness and accuracy are demonstrated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4133272PMC
http://dx.doi.org/10.1109/TIP.2014.2300751DOI Listing

Publication Analysis

Top Keywords

system automatic
12
left ventricular
12
ventricular myocardium
12
left ventricle
12
complete system
8
images shape
8
myocardial surfaces
8
left
6
automatic extraction
4
extraction left
4

Similar Publications

Some technical limitations to using the eccentric mode to measure peak eccentric strength of the hamstrings (PTH) were raised. PTH also has limited validity to predict performance or injury risk factor. Therefore, our aim was to compare PTH and other isokinetic variables tested in the eccentric and passive modes.

View Article and Find Full Text PDF

Lighting systems account for a significant proportion of energy consumption in buildings. Therefore, energy conservation within these systems can greatly enhance overall building energy efficiency. This study proposes a control strategy for LED lamps by adjusting lighting intensity and improving the performance of electric luminaires.

View Article and Find Full Text PDF

Fully automated in vivo screening system for multi-organ imaging and pharmaceutical evaluation.

Microsyst Nanoeng

January 2025

Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument, School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, 518000, Shenzhen, China.

Advancements in screening technologies employing small organisms have enabled deep profiling of compounds in vivo. However, current strategies for phenotyping of behaving animals, such as zebrafish, typically involve tedious manipulations. Here, we develop and validate a fully automated in vivo screening system (AISS) that integrates microfluidic technology and computer-vision-based control methods to enable rapid evaluation of biological responses of non-anesthetized zebrafish to molecular gradients.

View Article and Find Full Text PDF

Background: Studies suggest that less than 4% of patients with pulmonary embolisms (PEs) are managed in the outpatient setting. Strong evidence and multiple guidelines support the use of the Pulmonary Embolism Severity Index (PESI) for the identification of acute PE patients appropriate for outpatient management. However, calculating the PESI score can be inconvenient in a busy emergency department (ED).

View Article and Find Full Text PDF

Unveiling significant regrowth and potential risk of nontuberculous mycobacteria in hospital water supply system.

Water Res

January 2025

Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan; Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1, Komaba, Meguro, Tokyo 153-8904, Japan. Electronic address:

The health burden of waterborne nontuberculous mycobacteria (NTM) is a rising concern. While the water supply systems can serve as a potential reservoir for NTM, their abundance, diversity, and transmission pathways remain unknown. This study aimed to characterize the prevalence and regrowth of NTM in building water supply system in a hospital where many M.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!