This work describes a technique for the measurement of 222Rn by absorption in polycarbonate (PC) powder and liquid scintillation counting (LSC). The work is an improvement of the recently proposed method for 222Rn measurements by LSC of exposed PC grains. It is demonstrated that the use of PC powder as a 222Rn sampler improves 13.6 times the sampling efficiency and leads to 6.5 times smaller minimmal detectable activity concentrations (MDAC) compared with the PC grains used so far. For a 40-h exposure of 7.4-g PC powder to 222Rn in air, the MDAC with a RackBeta 1219 LS counter is 62 Bq m(-3) (assuming a 8-h sample counting time and 24-h background time). For the same conditions the estimated 222Rn MDAC with a Quantulus 1220 LS counter is 20 Bq m(-3). The proposed technique is suitable for radon in air and radon in soil-gas measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncu075 | DOI Listing |
Sci Rep
December 2024
Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki, 036-8564, Aomori, Japan.
Radon (Rn) and thoron (Rn) were reported as the highest contributors to natural radiation received by humans. Furthermore, radon has been stated as the second-highest cause of lung cancer. The concentrations of U and Th (the parent nuclide of radon and thoron, respectively) in nature vary with geological conditions and can be enhanced by human activities.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2024
Environmental Assessment Division, Indira Gandhi Center for Atomic Research, Kalpakkam, Chengalpattu District, Tamilnadu 603102, India.
Radiat Prot Dosimetry
November 2024
Institute for Radiological Science, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan.
222Rn is recognized as a matter of international concern for human health risk. Because 220Rn as well as 222Rn coexist in the natural environment, thoron sometimes influences the experiment for radon measurement. It is important to measure radon and thoron separately to evaluate the risk of the exposure to 222Rn.
View Article and Find Full Text PDFRadiat Prot Dosimetry
November 2024
Shanghai Institute of Measurement and Testing Technology, 1500 Zhang-Heng Road, Shanghai 201203, China.
To overcome the time-resolution limitation inherent in the airflow-through scintillation cell method for radon measurement, this study introduces a compartmental model elucidating the behaviors of radon and its progeny within such cells. The computed results of the normalized equilibrium functions derived from the compartmental model, provide quantitative insights into the equilibrium progression of 222Rn and its progeny over time, substantiating the identified time-resolution limitation of 2-3 hours. Laboratory experiments confirm the efficacy of the proposed correction algorithm, showcasing its ability to surmount the time-resolution limitation and achieve a rapid response in radon measurement using airflow-through scintillation cells.
View Article and Find Full Text PDFRadiat Prot Dosimetry
November 2024
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan.
The National Metrology Institute of Japan plan to use an inner-through-type ionization chamber (IC) as a working standard to calibrate radon monitors. Novel methods to calibrate the IC were described, and the calibration factor, CF [Bq m -3 A-1], of the IC with its expanded uncertainty (k = 2) was evaluated to be (2.0 ± 0.