Double-pass Mach-Zehnder fiber interferometer pH sensor.

J Biomed Opt

Nanyang Technological University, School of Chemical and Biomedical Engineering, Division of Bioengineering, 70 Nanyang Drive, Singapore 637457, Singapore.

Published: April 2014

A biocompatible fiber-optic pH sensor based on a unique double-pass Mach-Zehnder interferometer is proposed. pH responsive poly(2-hydroxyethyl methacrylate-co-2-(dimethylamino)ethyl methacrylate) hydrogel coating on the fiber swells/deswells in response to local pH, leading to refractive index changes that manifest as shifting of interference dips in the optical spectrum. The pH sensor is tested in spiked phosphate buffer saline and demonstrates high sensitivity of 1.71  nm/pH, pH 0.004 limit of detection with good responsiveness, repeatability, and stability. The proposed sensor has been successfully applied in monitoring the media pH in cell culture experiments to investigate the relationship between pH and cancer cell growth.

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.JBO.19.4.047002DOI Listing

Publication Analysis

Top Keywords

double-pass mach-zehnder
8
mach-zehnder fiber
4
fiber interferometer
4
sensor
4
interferometer sensor
4
sensor biocompatible
4
biocompatible fiber-optic
4
fiber-optic sensor
4
sensor based
4
based unique
4

Similar Publications

White light interferometry is a well established technique with diverse precision applications, however, the conventional interferometers such as Michelson, Mach-Zehnder or Linnik are large in size, demand tedious alignment for obtaining white light fringes, require noise-isolation techniques to achieve sub-nanometric stability and importantly, exhibit unbalanced dispersion causing uncertainty in absolute zero delay reference. Here, we demonstrate an ultrathin white light interferometer enabling picometer resolution by exploiting the wavefront division of a broadband incoherent light beam after transmission through a pair of micrometer thin identical glass plates. Spatial overlap between the two diffracted split wavefronts readily produce high-contrast and stable white light fringes, with unambiguous reference to absolute zero path-delay position.

View Article and Find Full Text PDF

A new optical probing method with increased interferometric sensitivity for a low-density gas jet characterization is presented. The proposed technique employs a Michelson interferometer with a self-imaging object arm, which enables the relay imaging of the object on itself, and in this way, the phase sensitivity of the device is increased by a double propagation of the object laser beam through the gas jet. The wavelength of 405 nm was chosen to further increase the sensitivity by increasing the probe wavenumber.

View Article and Find Full Text PDF

This paper demonstrates multiphoton excited fluorescence imaging through a polarisation maintaining multicore fiber (PM-MCF) while the fiber is dynamically deformed using all-proximal detection. Single-shot proximal measurement of the relative optical path lengths of all the cores of the PM-MCF in double pass is achieved using a Mach-Zehnder interferometer read out by a scientific CMOS camera operating at 416 Hz. A non-linear least squares fitting procedure is then employed to determine the deformation-induced lateral shift of the excitation spot at the distal tip of the PM-MCF.

View Article and Find Full Text PDF

A novel high-speed Mach-Zehnder modulator (MZM) fully integrated into a 90 nm CMOS process is presented. The MZM features 'double-pass' optical phase shifter segments, and the first use of integrated inductors in a 'velocity-matched' distributed-electrode configuration.

View Article and Find Full Text PDF

Double-pass Mach-Zehnder fiber interferometer pH sensor.

J Biomed Opt

April 2014

Nanyang Technological University, School of Chemical and Biomedical Engineering, Division of Bioengineering, 70 Nanyang Drive, Singapore 637457, Singapore.

A biocompatible fiber-optic pH sensor based on a unique double-pass Mach-Zehnder interferometer is proposed. pH responsive poly(2-hydroxyethyl methacrylate-co-2-(dimethylamino)ethyl methacrylate) hydrogel coating on the fiber swells/deswells in response to local pH, leading to refractive index changes that manifest as shifting of interference dips in the optical spectrum. The pH sensor is tested in spiked phosphate buffer saline and demonstrates high sensitivity of 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!