A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Six random specimens of daytime casual urine on different days are sufficient to estimate daily sodium/potassium ratio in comparison to 7-day 24-h urine collections. | LitMetric

The objective of this study was to determine the optimal number and type of casual (spot) urine specimens required to estimate an individual's urinary sodium/potassium (Na/K) ratio. A total of 48 participants, 25 men and 23 women, aged between 25 and 59 years, was recruited from healthy volunteers. The Na/K ratio in each casual urine and 7-day 24-h urine sample was measured. Correlation analysis and the quality of agreement by the Bland and Altman method between casual urine and 24-h urine were analyzed. The mean Na/K ratio of 7-day 24-h urine was 4.3. The mean Na/K ratio of six random specimens of daytime (collected between 09 and 17 hours) casual urine correlated most strongly with the Na/K ratio of 7-day 24-h urine (r=0.87). The bias for the mean Na/K ratio between 7-day 24-h urine and daytime casual urine was almost negligible (0.03), and the quality of agreement for the mean of the six random, daytime casual urine specimens on different days was similar to that of the 2-day 24-h urine samples for estimating 7-day 24-h values. Our findings show that the mean Na/K ratio of six random daytime casual urine specimens on different days was a good substitute for the 2-day 24-h urine Na/K ratio.

Download full-text PDF

Source
http://dx.doi.org/10.1038/hr.2014.76DOI Listing

Publication Analysis

Top Keywords

24-h urine
32
na/k ratio
32
casual urine
28
7-day 24-h
24
daytime casual
16
urine
16
urine specimens
12
ratio 7-day
12
ratio
9
24-h
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!