A case of arterial rupture of the profunda femoris arterial branches, following dynamic hip screw (DHS) fixation for an intertrochanteric femoral fracture, is presented. Bleeding is controlled by coil embolization, but, later on, the patient underwent orthopedic material removal due to an infection of a large femoral hematoma.