Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Dual-energy computed tomography (DECT) images may be underutilized for the evaluation of skeletal metastasis. Spectral parametric segmentation of DECT can produce bone-iodine separated images, which have the potential to detect bone metastases.
Purpose: To evaluate the potential of bone-iodine separation in the detection of bone metastasis with spectral parametric segmentation of DECT images which are acquired at clinical follow-up for patients with prior malignancy.
Material And Methods: The institutional review board approved the protocol of this retrospective review. Chest DECT scans using fast kV-switching between 80 and 140 kVp were included in this study. Bone-iodine separated reformatted images were produced by spectral parametric segmentation of synthesized monochromatic images. All chest CT images of 702 metastatic lesions from 54 patients were retrospectively evaluated in terms of visualization of metastatic lesions compared with (99m)Tc-MDP (methylene diphosphonate) whole-body bone scintigraphy (WBBS) as reference standard of diagnosis.
Results: Spectral parametric segmentation images of DECT visualized metastatic lesions in 92.3% (n = 648/702). Osteoblastic metastases were delineated as subtle enhancing lesions on DECT in comparison to WBBS.
Conclusion: Spectral parametric segmentation of iodine from cortical and medullary bone allowed visualization of bone metastasis. DECT might be utilized for the screening or detection of bone metastases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0284185114530105 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!