Objectives: Stable fixation of displaced type II distal clavicle fractures presents a challenge to the surgeon because of distal fragment comminution and the large deforming forces created by the weight of the arm. We hypothesized that suture fixation around the coracoid and interfragmentary suture fixation would adequately counteract these forces and lead to a high rate of union and restoration of function.
Design: This is a retrospective study of 20 sequential patients treated between 1997 and 2009.
Setting: In-patient operating room followed by the clinic.
Patients/participants: All patients presenting with acute displaced distal clavicle fractures to 2 surgeons were included. All patients completed the study without loss to follow-up.
Intervention: Open repair was performed by placing two #5 Fiberwire sutures around the coracoid and through drill holes in the clavicular shaft. Interfragmentary fixation was performed with figure-of-eight #2 Fiberwire sutures.
Main Outcome Measures: Patients evaluation included the American Shoulder and Elbow Surgeons scale, range of motion, radiographic evaluation, and patient satisfaction.
Results: All fractures healed without loss of reduction at an average of 2.6 months, and all patients were satisfied. American Shoulder and Elbow Surgeons score was 98.5 out of 100. Average follow-up was 7.1 years (range, 3.1-14.3 years). One postoperative wound hematoma and one superficial wound infection were treated nonoperatively.
Conclusions: Interfragmentary and coracoclavicular suture fixation for displaced acute distal clavicle fractures is a safe and effective treatment with an excellent union rate, low complication rate, and high patient satisfaction.
Level Of Evidence: Therapeutic level IV. See instructions for authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0000000000000122 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Department of Sports Orthopaedics, Klinikum rechts der Isar (Technical University of Munich), Ismaninger Straße 22, 81675, Munich, Germany.
Purpose: This study aims to describe a fixation technique for coronoid fractures using suture buttons, and to biomechanically evaluate this technique in comparison to screw fixation as a time-zero pilot study.
Methods: An O'Driscoll type 2 anteromedial coronoid facet (AMCF) fracture was simulated in 20 fresh-frozen human elbows. The specimens were randomized into two groups and fracture fixation was performed with either a suture button system or a 3.
Ann Plast Surg
December 2024
From the Department of Plastic and Reconstructive Surgery, National Cancer Center Hospital East, Kashiwa.
Objective: The impact of suture materials on surgical site infections (SSIs) has been well documented in various surgical fields; however, it has not been thoroughly examined in oral oncological surgery with free-flap reconstruction. This study aimed to evaluate the incidence of oral SSIs associated with the use of monofilament and braided sutures for flap fixation.
Methods: A retrospective chart review of patients who underwent oral oncological resection with free-flap reconstruction was conducted between May 2020 and April 2024.
Arthrosc Tech
December 2024
Queensland Unit for Advanced Shoulder Research (QUASR), Queensland University of Technology, Brisbane, Australia.
Tenodesis of the long head of biceps is a common shoulder surgical procedure. Tenodesis can be performed either arthroscopically or open and within the glenohumeral joint, within the bicipital groove, or below the pectoralis major tendon insertion. Arthroscopic tenodesis of the biceps tendon reduces the risk of infection.
View Article and Find Full Text PDFArthrosc Tech
December 2024
Department of Orthopaedic Surgery, University of California Irvine, Orange, California, U.S.A.
Acute, traumatic distal biceps tendon ruptures are a common injury in the middle-aged athletic male population, with direct anatomic surgical repair being the most effective technique to restore maximal strength. Multiple techniques for distal biceps tendon repair have been described, including single- or dual-incision approaches and tendon fixation with cortical buttons, interference screws, suture anchors, and transosseous sutures. In this Technical Note, we demonstrate an anatomic distal biceps tendon repair technique with a single-incision approach using 2 all-suture cortical buttons.
View Article and Find Full Text PDFArthrosc Tech
December 2024
Department of Orthopaedics, School of Medicine, Jichi Medical University, Shimotsuke, Japan.
Inside-out repair of meniscal tears is the gold standard surgical approach; however, its use is limited by the need for a posterior incision and neurovascular risk. In this Technical Report, we present details of the all-inside arthroscopic tie-grip approach for repairing a radial tear of the midbody of the lateral meniscus using an all-inside device (TRUESPAN) and a slotted cannula. In contrast to the inside-out approach, this technique helps reduce surgical invasiveness and provides stable fixation as the vertical mattress sutures bundle the circumferential fibers and act as rip stops for the horizontal sutures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!