Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The quality assurance tests for measuring the spatial orientations between tabletop, external patient positioning lasers, couch longitudinal moving direction, and imaging plane in a CT simulation system are a complicated and time-consuming process. We proposed a simple and efficient approach to acquire the angular deviations of spatial orientations between these components. An in-house cross-jig was used in this study. We found a relationship between the orientations of the jig's arms shown on the CT images and the orientations of the components in a CT simulator. We verified this relationship with 16 misalignment orientations of known errors, to simulate all possible deviation situations. Generally, the tabletop and external lasers system are mounted separately in a CT simulation system; the former is on the couch trail, the later is on the wall and ceiling. They are independent to each other and will cause different effects on CT images. We only need two scans to acquire the angular deviations of our system: i) when aligning the cross-jig with tabletop, we can check the orientations between the tabletop, couch longitudinal moving direction, and imaging plane; ii) while aligning the cross-jig with the external axial lasers, we will know the angular deviation between the lasers, couch longitudinal moving direction, and imaging plane. The CT simulator had been carefully examined by performing the QA procedures recommended by the AAPM Task Group 66. The measurements of the spatial orientations using the proposed method agree well with TG 66 recommendations. However, the time taken to perform the QA using our method is considerably shorter than the method described in TG 66--5 minutes versus 30 minutes. The deliberate misalignment orientations tests with known errors were detected successfully by our in-house analysis program. The maximum difference between the known errors and the measured angles is only 0.07°. We determined that the relationship between the orientations of the jig's arms and the orientations of the CT components. By means of quantifying the deviations in degree we can correct the errors accurately. This approach can also be used to inspect the spatial orientations of other imaging systems, such as PET-CT and MRI.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875483 | PMC |
http://dx.doi.org/10.1120/jacmp.v15i2.4544 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!