Here, we report a potentiometric method for detecting single platinum nanoparticles (Pt NPs) by measuring a change in open-circuit potential (OCP) instead of the current during single Pt NP collisions with the mercury-modified Pt ultramicroelectrode (Hg/Pt UME). Similar to the current-time (i-t) response reported previously at Hg/Pt UMEs, the OCP-time (v-t) response consists of repeated potential transient signals that return to the background level. This is because Hg poisons the Pt NP after collision with the Hg/Pt UME due to amalgamation and results in deactivation of the redox reaction. For individual Pt NP collisions the amplitude of the OCP signal reaches a maximum and decays to the background level at a slower rate compared to the comparable i-t response. Due to this, OCP events are broader and more symmetrical in shape compared to i-t "spikes." The collision frequency of Pt NPs derived from v-t plots (0.007 to 0.020 pM(-1) s(-1)) is in good agreement with the value derived from i-t plots recorded at Hg/Pt UMEs (0.016 to 0.024 pM(-1) s(-1)) under similar conditions and was found to scale linearly with Pt NP concentration. Similar to the current response, the amplitude of the OCP response increased with the NP's size. However, unlike the change in current in a i-t response, the change in OCP in a v-t response observed during single Pt NP collisions with Hg/Pt UME is larger than the estimated change in OCP based on the theory. Therefore, the Pt NP sizes derived from the v-t response did not correlate with the TEM-derived Pt NP sizes. In spite of these results the potentiometric method has great value for electroanalysis because of its significant advantages over the amperometric method such as a simpler apparatus and higher sensitivity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/nn500045m | DOI Listing |
J Am Chem Soc
December 2017
Center for Electrochemistry, Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States.
The electrocatalytic reduction of CO has been studied extensively and produces a number of products. The initial reaction in the CO reduction is often taken to be the 1e formation of the radical anion, CO. However, the electrochemical detection and characterization of CO is challenging because of the short lifetime of CO, which can dimerize and react with proton donors and even mild oxidants.
View Article and Find Full Text PDFACS Nano
May 2014
Department of Chemistry, The University of Texas at Austin , 1 University Station, Austin, Texas 78712, United States.
Here, we report a potentiometric method for detecting single platinum nanoparticles (Pt NPs) by measuring a change in open-circuit potential (OCP) instead of the current during single Pt NP collisions with the mercury-modified Pt ultramicroelectrode (Hg/Pt UME). Similar to the current-time (i-t) response reported previously at Hg/Pt UMEs, the OCP-time (v-t) response consists of repeated potential transient signals that return to the background level. This is because Hg poisons the Pt NP after collision with the Hg/Pt UME due to amalgamation and results in deactivation of the redox reaction.
View Article and Find Full Text PDFLangmuir
December 2013
Department of Chemistry, The University of Texas at Austin , 1 University Station, Austin, Texas 78712, United States.
Single-Pt nanoparticles (NPs) can be detected electrochemically by measuring the current-time (i-t) response associated with both hydrazine oxidation and proton reduction during individual Pt NP collisions with noncatalytic Hg- and Bi-modified Pt ultramicroelectrodes (Hg/Pt and Bi/Pt UMEs, respectively). At Hg/Pt UMEs, the i-t response for both hydrazine oxidation and proton reduction consists of repeated current "spikes" that return to the background level as Hg poisons the Pt NP after collision with the Hg/Pt UME due to amalgamation and deactivation of the redox reaction. Furthermore, at a Hg/Pt UME, the applied potential directly influences the interfacial surface tension (electrocapillarity) that also impacts the observed i-t response for single-Pt NP collisions for proton reduction that exhibits a faster decay of current (0.
View Article and Find Full Text PDFJ Am Chem Soc
January 2013
Department of Chemistry and Biochemistry, University of Texas at Austin, Austin, Texas 78712, USA.
Here we describe a very simple, reliable, low-cost electrochemical approach to detect single nanoparticles (NPs) and evaluate NP size distributions and catalytic activity in a fast and reproducible manner. Single NPs are detected through an increase in current caused by electrocatalytic oxidation of N(2)H(4) at the surface of the NP when it contacts a Hg-modified Pt ultramicroelectrode (Hg/Pt UME). Once the NP contacts the Hg/Pt UME, Hg poisons the Pt NP, deactivating the N(2)H(4) oxidation reaction.
View Article and Find Full Text PDFJ Anal Methods Chem
August 2012
Departamento de Química Inorgânica, Instituto de Química, Centro de Tecnologia, UFRJ, Avenida Athos da Silveira Ramos 149, Bloco A, Laboratório 634A, Cidade Universitária, 21941-909 Rio de Janeiro, RJ, Brazil.
This paper describes the applicability of a Hg-electroplated-Pt ultramicroelectrode in the quantification of elemental sulphur in naphtha samples by square-wave voltammetry. A reproducible deposition methodology was studied and is reported in this paper. This methodology is innovative and relies on the quality of the mercury stock solution to obtain reproducible surfaces required for the analytical methodology.