The main aim of the European Union Water Framework Directive (WFD) (2000/60/EC) is to protect rivers, lakes, coastal waters and groundwaters (EC 2000). The implementation of the WFD requires monitoring the concentration levels of several priority pollutants such as nonylphenol ethoxylates (NPEOs) and nonylphenol (NP) in the area of EU. The present practices for determining the concentration levels of various pollutants are, in many respects, insufficient, and there is an urgent need to develop more cost-effective sampling methods. A passive sampling tool named Chemcatcher was tested for monitoring NPEOs and NP in aqueous media. These environmentally harmful substances have been widely used in different household and industrial applications, and they affect aquatic ecosystems, for example, by acting as endocrine disrupting compounds. The suitability of different receiving phases which were sulfonated styrene-divinylbenzene reversed phase polymer (SDB-RPS), standard styrene-divinyl benzene polymer (SDB-XC) and C-18 (octadecyl) was assessed in laboratory and field trials. The effect of a diffusion membrane on the accumulation of studied compounds was also investigated. The SDB-XC and C-18 receiving phases collected the NPEOs and NP most effectively. The water flow affected the accumulation factor of the studied substances in the field trials, and the water concentrations calculated using sampling rates were tenfold lower than those measured with conventional spot sampling. The concentration of the analytes in spot samples taken from the sampling sites might be higher because in that case, the particle-bound fraction is also measured. The NPEOs readily attach to suspended matter, and therefore, the total concentration of such compounds in water is much higher. Also, the spot samples were not taken daily but once a week, while the passive samplers collected the compounds continuously for 2- or 4-week time periods. This may cause differences when comparing the results of those two methods as well. Both techniques can be applied for monitoring the concentration levels at different sampling sites, but the calculated and measured analyte concentrations in surrounding water are not necessarily comparable with each other. More experiments are still needed to study the effect of hydrological issues and humic substances on the accumulation of chemicals. However, the Chemcatcher passive sampler gives valuable information about the mean concentration levels of studied compounds during 2- or 4-week sampling period. This is important for comparison of annual monitoring results, especially in sampling sites with rapidly fluctuating concentrations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11356-014-2828-5 | DOI Listing |
DNA Cell Biol
January 2025
Department of Anesthesiology, The Third Affiliated Hospital of Qiqihar Medical University, Qiqihar, China.
Lung cancer represents a significant global health burden, with non-small cell lung cancer (NSCLC) being the most common subtype. The current standard of care for NSCLC has limited efficacy, highlighting the necessity for innovative treatment options. Lidocaine, traditionally recognized as a local anesthetic, has emerged as a compound with potential antitumor and anti-inflammatory capabilities.
View Article and Find Full Text PDFDiabetes Care
January 2025
Department of Population and Public Health Sciences, Keck School of Medicine, University of Southern California, Los Angeles, CA.
Objective: We investigated associations between per- and polyfluoroalkyl substances (PFAS) and changes in diabetes indicators from pregnancy to 12 years after delivery among women with a history of gestational diabetes mellitus (GDM).
Research Design And Methods: Eighty Hispanic women with GDM history were followed from the third trimester of pregnancy to 12 years after delivery. Oral and intravenous glucose tolerance tests were conducted during follow-up.
Chem Asian J
January 2025
University of Macau, Institute of Applied Physics and Materials Engineering, MACAO.
In recent years, carbon dots (CDs) with fluorescence imaging function have been widely used in biomedicine, electronic manufacturing and environmental monitoring. However, monochromatic fluorescence is often limited by the application environment and loses its effectiveness. Here, we carefully designed white fluorescent CDs (WF-CDs) by solvothermal method, which is used for fluorescence imaging applications under different environmental conditions.
View Article and Find Full Text PDFBiol Trace Elem Res
January 2025
College of Arts & Sciences, American University of Kuwait, P.O. Box 3323, 13034, Safat, Kuwait.
Infants are particularly vulnerable to exposure to toxic trace elements due to their developmental stage and behaviors such as mouthing and chewing on toys. Chemical exposure to heavy metals in infants' toys is a significant concern as it poses a threat to their health and well-being. Therefore, quality control measures are essential to prevent infants' exposure to potentially harmful metals.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!