Objective: To explore the application value of the MI-3DVS in patients with hepatic artery variation receiving duodenopancreatectomy.
Methods: A total of 114 patients who had undergone pancreatoduodenectomy were retrospectively summarized and analyzed during January 2010 to July 2012. The clinical data of 64-slice multidetector CT angiography (64-MDCTA) scanning was introduced into MI-3DVS for procedural segmentation, registration and 3-dimensional reconstruction. Based on the reconstructed 3-dimensional model, the origination and bifurcations of variant hepatic artery was observed. And its anatomical relationships with abdominal organs and vessels were also observed. Thereafter, preoperative procedures planning was formulated. The findings were compared to those found during the operation and by postoperative digital subtraction angiography (DSA) of coeliac artery.
Results: The abdominal 3D models can clearly display the size and shape of tumor, the origin and course of the blood vessels, as well as the 3D anatomic relationship between tumors and organs, blood vessels. A total of 14 cases (12.3%, 14/114) were found with variant, including 9 cases (7.9%) with replaced right hepatic artery arising from superior mesenteric artery, 3 cases (2.6%) with replaced common hepatic artery arising from superior mesenteric artery, 2 cases (1.8%) with replaced left hepatic artery arising from left gastric artery. The 14 patients all received standard procedures of duodenopancreatectomy. Compared to the intraoperative findings and postoperative DSA examination, the sensitivity, specificity and accuracy of MI-3DVS to variant hepatic artery is 100%. The preoperative planning guided by MI-3DVS is in line with the intraoperative findings.No postoperative complications occurred in all 14 patients, including hepatic abscesses, biliary fistula and liver failure.
Conclusions: MI-3DVS can accurately diagnose hepatic artery variation before duodenopancreatectomy. Therefore, it contributes to the formulation of preoperative surgical plans.It also increases the success rate of the surgical operations and decreases the occurrence of postoperative complications.
Download full-text PDF |
Source |
---|
Port J Card Thorac Vasc Surg
January 2025
Angiology and Vascular Surgery, Unidade Local de Saúde de São João; Surgery and Physiology, Faculdade de Medicina da Universidade do Porto, Portugal.
A 44 year-old previously healthy woman presented a persistent epigastric pain. Computed tomography revealed a saccular aneurysm with a diameter of 25x20 mm in the first jejunal artery and also a stenosis in the celiac trunk associated with median arcuate ligament syndrome, turning the hepatic perfusion dependent of the gastroduodenal artery flow. Through a midline laparotomy, celiac axis was exposed, and median arcuate ligament released for median arcuate ligament syndrome treatment.
View Article and Find Full Text PDFInterdiscip Cardiovasc Thorac Surg
January 2025
Department of Pediatrics, Kansai Medical University, Hirakata, Osaka, Japan.
Objectives: This retrospective study aimed to investigate the feasibility of surgical closure of ventricular septal defect in children with trisomy 18 by assessing perioperative events and long-term survival.
Methods: From April 2008 to March 2024, 41 consecutive patients were referred to us for ventricular septal defect surgery. The defect was closed in 35 patients at the end (median age, 16 months; median body weight, 5.
Curr Oncol
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Leipzig, 04103 Leipzig, Germany.
Background: The aim of this study was to compare microwave ablation (MWA) with and without prior placement of an intra-arterial catheter for the purpose of application of contrast medium (CM).
Methods: 148 patients (45 female, 65.1 ± 14.
Ann Card Anaesth
January 2025
Department of Cardiothoracic and Vascular Anaesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, India.
Background: This study aimed to assess the accuracy of tricuspid spectral Doppler (E/A) and tissue Doppler parameters (E/E') to diagnose right ventricular diastolic dysfunction (RVDD) in comparison to American Society of Echocardiography (ASE criteria) in pediatric tetralogy of Fallot (TOF) patients after surgical repair.
Methods: This prospective, observational study was done at a tertiary care hospital involving 40 pediatric TOF patients aged less than 2 years who underwent complete intracardiac repair with cardiopulmonary bypass (CPB). Echocardiographic observations were made using a pediatric transesophageal echocardiography probe after surgical repair in the post-CPB period.
Minerva Anestesiol
January 2025
Transplant Anesthesia and Critical Care, Pisa NHS and University Hospitals, Pisa, Italy -
Intraoperative hemodynamic monitoring is crucial for managing patients with end-stage liver disease (ESLD) undergoing orthotopic liver transplantation (OLT) due to their complex cardiovascular and pulmonary abnormalities. Traditionally, pulmonary artery catheterization (PAC) has been the standard for hemodynamic monitoring during OLT. However, the use of transesophageal echocardiography (TEE) has increased due to its real-time visualization of cardiac and vascular structures, which aids in managing hemodynamic instability during the three surgical phases of OLT: pre-anhepatic, anhepatic, and neo-hepatic.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!