We present a method for measuring beat-to-beat heart rate from ballistocardiograms acquired with force sensors. First, a model for the heartbeat shape is adaptively inferred from the signal using hierarchical clustering. Then, beat-to-beat intervals are detected by finding positions where the heartbeat shape best fits the signal. The method was validated with overnight recordings from 46 subjects in varying setups (sleep clinic, home, single bed, double bed, two sensor types). The mean beat-to-beat interval error was 13 ms and on an average 54% of the beat-to-beat intervals were detected. The method is part of a home-use e-health system for an unobtrusive sleep measurement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/JBHI.2014.2314144 | DOI Listing |
Biosensors (Basel)
December 2024
Optoelectronics and Measurement Techniques Research Unit, University of Oulu, 90570 Oulu, Finland.
There is an ongoing search for a reliable and continuous method of noninvasive blood pressure (BP) tracking. In this study, we investigate the feasibility of utilizing seismocardiogram (SCG) signals, i.e.
View Article and Find Full Text PDFComput Methods Programs Biomed
December 2024
Centro de Investigación e Innovación en Bioingeniería (Ci2B), Universitat Politècnica de València, Valencia, Spain. Electronic address:
Background And Objective: In silico human models are being used more and more to predict the potential proarrhythmic risk of compounds. It has been shown that incorporation of the dynamics of drug-hERG channel interactions can have an important impact on the action potential duration (APD) at normal heart rates. Our aim is to investigate the relevance of drug dynamics on other important biomarkers of proarrhythmic risk.
View Article and Find Full Text PDFJ Sports Sci
December 2024
Faculty of Kinesiology and Health Studies, University of Regina, Regina, SK, Canada.
Assessment of cerebral oxygenation during repeated squat stands following an acute sport-related concussion (SRC) has the potential to identify physiological changes following SRC. All varsity university athletes completed a pre-season assessment and 53 were followed up within 5-days of suffering an SRC. Of the 53 participants, 29 had continuous beat-to-beat blood pressure (BP; sampled at 200 hz) collected by finger photoplethysmography, and 53 had right prefrontal cortex oxygenation collected by near-infrared spectroscopy (NIRS; sampled at 10 hz).
View Article and Find Full Text PDFNovel Insights Continuous intrapartum fetal heart rate assessment by fetal scalp electrode may record arrythmias like recurrent atrial ectopic beats and depict an increased fetal heart rate variability mimicking a ZigZag pattern. Introduction Fetal scalp electrode (FSE) is considered the gold standard for the intrapartum monitoring of the fetal heart rate (FHR) being associated with the lowest rate of signal loss and artifacts including the recording of the maternal heart rate. FSE acquires a fetal electrocardiogram and evaluates the time intervals between successive R waves.
View Article and Find Full Text PDFMed Sci Sports Exerc
December 2024
Integrative Physiology Laboratory, Department of Kinesiology and Nutrition, University of Illinois Chicago, Chicago, IL.
Introduction: Individuals with Down syndrome (DS) exhibit autonomic dysfunction, which contributes to reduced work capacity. The metaboreflex produces exercise-induced sympathoexcitation and can be assessed via post-exercise muscle ischemia (PEMI). Blunted sympathoexcitation is common in individuals with DS and contributes to the physiological basis for reduced work capacity observed this population, but the influence of the metaboreflex is unknown.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!