We report a successful perventricular closure of an apical muscular ventricular septal defect (mVSD) by a modified technique. An eight-month-old infant, weighing 6.5 kilograms, presented with refractory heart failure. The transthoracic echocardiogram showed multiple apical mVSDs with the largest one measuring 10 mm. perventricular device closure using a 12 mm Amplatzer mVSD occluder was planned. The left ventricular disk was positioned approximating the interventricular septum; however, the right ventricular (RV) disk was deployed on the free wall of the RV due to an absent apical muscular septum and a small cavity at the apex. The RV disk of the device was covered using an autologous pericardium. His heart failure improved during follow-up.