Background: A growing number of dental implants are being placed each year in the United States. This upward trend is associated with an increased incidence of comorbidities. In this regard, use of a drill stop has the potential to decrease unintended consequences of overdrilling the depth of an osteotomy.

Methods: The authors did not find any studies in the dental literature in which researchers assessed the safety and effectiveness of using drill stops on twist drills. Nevertheless, the advantages of utilizing drill stops and the undesired results due to excessive drilling can be reasonably deduced.

Results: The authors describe the following clinically relevant issues pertaining to overdrilling of osteotomies for dental implants: the anatomical effect of excessive drilling in different sections of the oral cavity, reasons for excessive drilling, methods to avoid overlengthening of implant sites and benefits of using drill stops on twist drills.

Conclusions: Use of drill stops enhances safety, accuracy and efficiency when creating an osteotomy. Drill stops also reduce the clinicians and patients stress during operative procedures.

Practical Implications: Drills stops can be beneficial when utilized in situations in which there is reduced visibility, making it difficult to read the lines on a twist drill. They also are helpful when there is a dearth of bone over the mandibular or mental nerves, and precisely lengthened osteotomies are needed to avoid nerve injuries.

Download full-text PDF

Source
http://dx.doi.org/10.14219/jada.2014.10DOI Listing

Publication Analysis

Top Keywords

drill stops
24
stops twist
12
dental implants
12
excessive drilling
12
drill
8
twist drills
8
efficiency creating
8
osteotomies dental
8
stops
6
twist
4

Similar Publications

The endoscopic transsphenoidal approach is a common approach used in skull base neurosurgery to reach the sellar region. One of the intraoperative risks of this approach is intraoperative bleeding out of the carotid artery. Gentle drilling can prevent carotid artery injury.

View Article and Find Full Text PDF

The authors present two cases of mouth floor hemorrhage consequences of implant placement within the atrophic anterior mandible. In one patient, the implant placement was associated with the guided bone regeneration (GBR) technique. This serious complication has been widely described in the literature, especially in the anterior mandible area.

View Article and Find Full Text PDF

Purpose: We conducted a phase I/II study evaluating nivolumab plus doxorubicin, vinblastine, dacarbazine (N-AVD) as frontline therapy for treatment-naïve older adults (OA) with classical Hodgkin lymphoma (cHL; ClinicalTrials.gov identifier: NCT03033914).

Methods: Patients age ≥60 years with newly diagnosed, any stage, cHL were treated with six cycles of AVD at standard doses plus nivolumab 240 mg intravenously once every 2 weeks (on days 1 and 15) of each cycle.

View Article and Find Full Text PDF

Recreational team sports have received great acceptance lately, in different populations, indicating encouraging results in health-related quality of life. This study examined the efficacy of a 3-month basketball exercise program on selected indices of health (body mass-BM, body fat-BF, blood pressure-BP), functional capacity (flexibility of lower and upper limbs, balance), and physical fitness (maximum strength of lower limbs, trunk and handgrip, aerobic capacity) in middle-aged individuals. Forty middle-aged individuals (males and females; 40-55 years old) were randomly divided into (a) exercise (EG; = 20) and (b) control groups (CG; = 20).

View Article and Find Full Text PDF

Research on process parameter optimization of irregular coal face.

Sci Rep

May 2024

College of Energy and Mining Engineering, Shandong University of Science and Technology, Qingdao, 266590, People's Republic of China.

Based on the engineering background of 1353 working face in Daizhuang Coalmine, the paper identifies three primary issues with the working face mining process: conventional pressure relief means are limited, risk of impact and the length of working face changes, It also proposes comprehensive control measures to improve the blasting roof cutting scheme, optimize mining speed and the location of the stopping line. The three improvement measures mentioned above are simulated numerically, and the effects of the drilling and blasting plan, mining speed, and stopping line location on stress distribution are determined. The results show that by implementing the three improvement measures, the stress variation interval can be efficiently controlled and the working face's production safety can be increased.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!