The new oxofluoride FeSeO3F, which is isostructural with FeTeO3F and GaTeO3F, was prepared by hydrothermal synthesis, and its structure was determined by X-ray diffraction. The magnetic properties of FeSeO3F were characterized by magnetic susceptibility and specific heat measurements, by evaluating its spin exchanges on the basis of density functional theory (DFT) calculations, and by performing a quantum Monte Carlo simulation of the magnetic susceptibility. FeSeO3F crystallizes in the monoclinic space group P21/n and has one unique Se(4+) ion and one unique Fe(3+) ion. The building blocks of FeSeO3F are [SeO3] trigonal pyramids and cis-[FeO4F2] distorted octahedra. The cis-[FeO4F2] octahedra are condensed by sharing the O-O and F-F edges alternatingly to form [FeO3F]∞ chains, which are interconnected via the [SeO3] pyramids by corner-sharing. The magnetic susceptibility of FeSeO3F is characterized by a broad maximum at 75(2) K and a long-range antiferromagnetic order below ∼45 K. The latter is observed by magnetic susceptibility and specific heat measurements. DFT calculations show that the Fe-F-Fe spin exchange is stronger than the Fe-O-Fe exchange, so each [FeO3F]∞ chain is a Heisenberg antiferromagnetic chain with alternating antiferromagnetic spin exchanges. The temperature dependence of the magnetic susceptibility is well-reproduced by a quantum-Monte Carlo simulation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ic5003995 | DOI Listing |
Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts.
View Article and Find Full Text PDFACS Omega
January 2025
Kirensky Institute of Physics, Federal Research Center KSC SB RAS, 50/38 Akademgorodok, Krasnoyarsk 330036, Russia.
The magnetization and anisotropy of magnetic susceptibility of a 5CB nematic liquid crystal doped three extracts containing chlorophylls a and b and carotenoids in different weight percentage has been studied. The extracts have been dissolved in the liquid crystal matrix at a concentration of 2%. The magnetic susceptibility of the substances has been measured by the Faraday-Curie balance method.
View Article and Find Full Text PDFJ Biochem Mol Toxicol
February 2025
Department of Chemistry, Science Faculty, Karabuk University, Karabuk, Turkey.
In this study, four novels 2,5,6-trisubstituted imidazothiadiazole derivative ligands and their Ag(I) complexes were synthesized and characterized using various spectroscopic analysis techniques. First, imidazo[2,1-b][1,3,4]thiadiazole derivative (3) was obtained from the reaction of 5-amino-1,3,4-thiadiazole-2-thiol with benzyl bromide in the presence of KOH in an ethanolic medium. In the next step, the resultant compound reacted sequentially with four substituted phenacyl bromide derivatives (4a-4d) under refluxed ethanol for 24 h to obtain substituted 2-(benzylthio)-6-phenylimidazo[2,1-b][1,3,4]thiadiazole derivatives (5-8).
View Article and Find Full Text PDFZ Med Phys
January 2025
Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland.
Purpose: This study aims to evaluate the feasibility of structural sub-millimeter isotropic brain MRI at 0.55 T using a 3D half-radial dual-echo balanced steady-state free precession sequence, termed bSTAR and to assess its potential for high-resolution magnetization transfer imaging.
Methods: Phantom and in-vivo imaging of three healthy volunteers was performed on a low-field 0.
Plast Reconstr Surg Glob Open
January 2025
From the Section General Internal Medicine, Department of Internal Medicine, Amsterdam Public Health Research Institute, Amsterdam University Medical Centers, Amsterdam, The Netherlands.
Background: Explantation often alleviates symptoms in women with breast implant illness. However, persistent complaints in some cases may be linked to persistent silicone-induced inflammation from residual silicone particles. Positron emission tomography (PET) imaging could potentially detect this inflammation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!