Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle positioning and with general guide pin locator positioning provided by equipment manufacturers. The screw reset rate, screw parallelism, triangle area formed by the link line of the entry point of 3 guide pins, and maximum vertical load bearing of the femoral neck after internal fixation were recorded. As expected, the triangle area was largest in the self-designed positioning group, followed by the general positioning group and the freehand positioning group. The difference among the 3 groups was statistically significant (P<.05). Anteroposterior and lateral radiographs showed that the screws were more parallel in the self-designed positioning group and general positioning group compared with the freehand positioning group (P<.05). The screw reset rate in the self-designed positioning group was significantly lower than that in the general positioning group and the freehand positioning group (P<.05). Maximum bearing load among the 3 groups was equivalent, showing no statistically significant difference (P>.05). The authors’ self-designed guide pin positioning system has the potential to accurately insert cannulated screws in femoral neck fractures and may reduce bone loss and unnecessary radiation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/01477447-20131219-11 | DOI Listing |
J Orthop Translat
January 2025
Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, People's Republic of China.
Background: RANKL and SCLEROSTIN antibodies have provided a strong effective choice for treating osteoporosis in the past years, which suggested novel molecular target identification and therapeutic strategies development are important for the treatment of osteoporosis. The therapeutic effect of verapamil, a drug previously used for cardiovascular diseases, on diabetes was due to the inhibition of TXNIP expression, which has also been reported as a target in mice osteoporosis. Whether verapamil-inhibited TXNIP expression is related to osteoporosis and how it works on the molecular level is worthy to be explored.
View Article and Find Full Text PDFJ Endocr Soc
January 2025
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford OX3 7LD, UK.
Purpose: To describe diagnostic approaches and management strategies for patients with primary hyperparathyroidism (PHPT) and recent fracture in England.
Methods: We developed a survey based on a patient at high fracture risk and a new diagnosis of probable PHPT. The survey was circulated among 50 secondary care professionals identified by the Society for Endocrinology Calcium and Bone special interest group.
J Bone Joint Surg Am
January 2025
Leeds Institute of Health Sciences, School of Medicine, University of Leeds, Leeds, West Yorkshire, England.
Background: In this study, we estimated the risk of surgically treated postoperative periprosthetic femoral fractures (POPFFs) associated with femoral implants frequently used for total hip arthroplasty (THA).
Methods: In this cohort study of patients who underwent primary THA in England between January 1, 2004, and December 31, 2020, POPFFs were identified from prospectively collected revision records and national hospital records. POPFF incidence rates, adjusting for potential confounders, were estimated for common stems.
Acta Orthop Traumatol Turc
December 2024
Department of Orthopaedics and Traumatology, Izmir Katip Celebi University, Ataturk Training and Research Hospital, Izmir, Türkiye.
Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.
Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.
Cureus
December 2024
Department of Rehabilitation Medicine, School of Medicine, Showa University, Tokyo, JPN.
Tetanus is a rare but life-threatening neurological disorder caused by neurotoxins produced by . Although mortality rates have significantly decreased with modern intensive care, severe cases remain challenging due to prolonged Intensive Care Unit (ICU) stays, complications, and rehabilitation barriers. We report the case of an 81-year-old male with a history of hypertension and femoral neck fracture who developed severe tetanus following a contaminated forehead laceration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!