Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of the study was to validate a semiquantitative analytical method to identify the aluminium(III) [Al(III)] concentration in 99Mo/99mTc generator eluates to check the European Pharmacopoeia (Ph. Eur.) requirement (<5 μg/ml). Three different solutions measuring 20 ml - 0.2% 1,10-phenanthroline, 0.05% chrome azurol S and 20% hexamethylenetetramine - were prepared. A cellulose filter paper was subsequently immersed in them, dried overnight at room temperature and cut into rectangles. A volume of 5 μl of first eluates of various 99Mo/99mTc generators was placed onto a reagent paper and the spot colour was compared with a standard aluminium solutions scale (0-100 μg/ml). A cyan/magenta/yellow/key (CMYK) model analysis was adapted to quantify the intensity of colour on the paper, and the presence of aluminium in the eluates was detected by a spectrophotometer. Small changes in standard solution pH (4.1-5.2) and chrome azurol S concentration did not affect the analysis. The cyan channel image analysis was proportional to the Al3+ solution concentration (y=25 019x+1489, R2=0.9554 within 2.5-8 μg/ml). The detection limit for aluminium by the visual test method is about 1 μg/ml, and fading is absent. The cyan channel image analysis method is independent of the observer and is applicable for the evaluation of the chemical purity of 99Mo/99mTc generator eluates. Our colorimetric 'spot test' is advantageous for the visual evaluation of Al pertechnetate concentrations as required by Ph. Eur. showing a sensitivity and a limit of detection superior to that of commercially available spot systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MNM.0000000000000108 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!