(14)N nuclear quadrupole resonance (NQR) in two known polymorphs of famotidine was measured. At room temperature, seven quadrupolar sets of transition frequencies (ν(+), ν(-), and ν(0)) corresponding to seven different nitrogen sites in the crystal structure of each of the two polymorphs were found. This confirms the expected ability of NQR to distinguish polymorph B from its analog A. NQR can also measure their ratio in a solid mixture and in the final dosage form, that is, a tablet. The NQR frequencies, line shapes, and tentative assignation to all seven molecular (14)N atoms were obtained. Unravelment of these two entangled NQR spectra presents a valuable contribution to the NQR database and enables studies of some possible correlations therein. Moreover, nondestructive (14)N NQR studies of commercial famotidine tablets can reveal some details of the drug fabrication process connected with compression.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jps.23956DOI Listing

Publication Analysis

Top Keywords

nuclear quadrupole
8
quadrupole resonance
8
nqr
7
¹⁴n nuclear
4
resonance study
4
study polymorphism
4
polymorphism famotidine
4
famotidine 14n
4
14n nuclear
4
resonance nqr
4

Similar Publications

Conformational Space of 3-Chloropropionic Acid in Gas Phase Explored by Rotational Spectroscopy.

J Phys Chem A

December 2024

Departamento de Química Física y Química Inorgánica, Facultad de Ciencias─I.U. CINQUIMA, Paseo de Belén, 7, 47011 Valladolid, Spain.

The conformational space of 3-chloropropionic acid has been studied under the isolated conditions of a supersonic expansion using Stark-modulated free-jet absorption millimeter-wave and centimeter-wave chirped-pulse Fourier transform microwave spectroscopy techniques. The rotational spectra originating from the three most stable conformers including Cl and Cl isotopologues were observed in both experiments using helium expansion while a partial conformational relaxation involving skeletal rearrangements takes place in an argon expansion. The rotational parameters, geometries, and energy order were determined from the experiment, allowing a comparison with quantum chemical predictions.

View Article and Find Full Text PDF

Mass-spectrometry-based assays nowadays play an essential role in biomedical research and clinical applications. There are different types of commercial mass spectrometers on the market today, and triple quadrupole (QqQ) is one of the time-honored systems. Here, we overview the main areas of QqQ applications in biomedicine and assess the current level, evolution, and trends in the use of QqQ in these areas.

View Article and Find Full Text PDF

A versatile setup for hydrogen isotope permeation studies.

Rev Sci Instrum

December 2024

Max-Planck-Insitut für Plasmaphysik, Boltzmannstrasse 2, Garching D-85748, Germany.

The Testbed for Analysis of Permeation of Atoms in Samples (TAPAS) is an experimental setup for ion-driven permeation studies with a focus on investigating wall materials for nuclear fusion devices. A monoenergetic, mass-filtered high-intensity keV ion beam is focused and directed onto the permeation sample by electrostatic ion optics and decelerated to the desired ion energy by a dedicated set of apertures close to the sample. We were able to obtain ion energies as low as 170 eV/D with a D3+ ion beam with an ion flux density of the order of 1020 D/m2s on a beam-wetted area of ∼33 mm2.

View Article and Find Full Text PDF

Rationale: The present study aims to establish structures of the degradation products of an anti-diabetic drug, Imeglimin (IMG) approved for the treatment of type 2 diabetes mellitus in the year 2021. Degradation pathways are proposed along with in silico toxicity assessments of the observed degradation products (DPs) of the drug.

Methods: A reversed-phase high-performance liquid chromatography (RP-HPLC), equipped with a photodiode array detector, was used to separate the observed DPs with a Phenomenex Luna PFP (250 × 4.

View Article and Find Full Text PDF

Tandem quadrupole inductively coupled plasma mass spectrometry has the potential capability to measure I at extremely low concentration if spectral interferences from Xe and IH can be eliminated effectively. Ozone was introduced as the reaction gas, resulting significantly improved reactions of (I→IO) and (I→IO ), and permitted the highly sensitive measurement of I as IO and IO , helping eliminate spectral interferences related to Xe and IH . In isotopic ratio (I/I) analysis by measuring (I→IO )/(I→IO ), a blank ratio of 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!