Nutritional recommendations for synchronized swimming.

Int J Sport Nutr Exerc Metab

Alberta Health Services, Nutrition & Food Services, Alberta, Canada.

Published: August 2014

The sport of synchronized swimming is unique, because it combines speed, power, and endurance with precise synchronized movements and high-risk acrobatic maneuvers. Athletes must train and compete while spending a great amount of time underwater, upside down, and without the luxury of easily available oxygen. This review assesses the scientific evidence with respect to the physiological demands, energy expenditure, and body composition in these athletes. The role of appropriate energy requirements and guidelines for carbohydrate, protein, fat, and micronutrients for elite synchronized swimmers are reviewed. Because of the aesthetic nature of the sport, which prioritizes leanness, the risks of energy and macronutrient deficiencies are of significant concern. Relative Energy Deficiency in Sport and disordered eating/eating disorders are also of concern for these female athletes. An approach to the healthy management of body composition in synchronized swimming is outlined. Synchronized swimmers should be encouraged to consume a well-balanced diet with sufficient energy to meet demands and to time the intake of carbohydrate, protein, and fat to optimize performance and body composition. Micronutrients of concern for this female athlete population include iron, calcium, and vitamin D. This article reviews the physiological demands of synchronized swimming and makes nutritional recommendations for recovery, training, and competition to help optimize athletic performance and to reduce risks for weight-related medical issues that are of particular concern for elite synchronized swimmers.

Download full-text PDF

Source
http://dx.doi.org/10.1123/ijsnem.2014-0013DOI Listing

Publication Analysis

Top Keywords

synchronized swimming
16
body composition
12
synchronized swimmers
12
nutritional recommendations
8
synchronized
8
physiological demands
8
carbohydrate protein
8
protein fat
8
elite synchronized
8
concern female
8

Similar Publications

Taylor's swimming sheet near a soft boundary.

Soft Matter

January 2025

Univ. Bordeaux, CNRS, LOMA, UMR 5798, F-33405 Talence, France.

In 1951, G. I. Taylor modeled swimming microorganisms by hypothesizing an infinite sheet in 2D moving in a viscous medium due to a wave passing through it.

View Article and Find Full Text PDF

Non-invasive eye tracking and retinal view reconstruction in free swimming schooling fish.

Commun Biol

December 2024

Centre for the Advanced Study of Collective Behaviour, University of Konstanz, 78464, Konstanz, Germany.

Eye tracking has emerged as a key method for understanding how animals process visual information, identifying crucial elements of perception and attention. Traditional fish eye tracking often alters animal behavior due to invasive techniques, while non-invasive methods are limited to either 2D tracking or restricting animals after training. Our study introduces a non-invasive technique for tracking and reconstructing the retinal view of free-swimming fish in a large 3D arena without behavioral training.

View Article and Find Full Text PDF

Magnetic control of soft microrobots near step-out frequency: Characterization and analysis.

Comput Struct Biotechnol J

December 2024

RAM-Robotics and Mechatronics, University of Twente, Enschede, 7500 AE, the Netherlands.

Magnetically actuated soft microrobots hold promise for biomedical applications that necessitate precise control and adaptability in complex environments. These microrobots can be accurately steered below their step-out frequencies where they exhibit synchronized motion with external magnetic fields. However, the step-out frequencies of soft microrobots have not been investigated yet, as opposed to their rigid counterparts.

View Article and Find Full Text PDF

This study questioned the influence of unilateral physical impairment on controlling inter-limb coordination, notably the coordination symmetry. We investigated whether unilateral physical impairment and unilateral breathing preference led to motor coordination asymmetry in eleven elite Para swimmers during 10 times 25 m in front crawl incremented in speed. Multicamera video system and five inertial measurement units were used to assess arm and leg phases and to compute symmetry of arm coordination and of arm-leg synchronisation.

View Article and Find Full Text PDF

Determining Validity and Reliability of an In-Field Performance Analysis System for Swimming.

Sensors (Basel)

November 2024

Department of Environmental and Bioscience, School of Business, Innovation and Sustainability, Halmstad University, 30118 Halmstad, Sweden.

Article Synopsis
  • The study aimed to validate a mobile performance analysis system (PAS) for measuring swimming performance, using a Kistler starting block with force plates and 2D cameras as a reference.
  • It involved 47 volunteers from the Swiss national swimming teams, including Olympic medalists, and analyzed 25 performance parameters, finding high validity for 7 of them.
  • The PAS demonstrated strong interrater reliability for 21 parameters, providing reference values for junior and adult swimmers to assess start, turn, and swimming performance effectively.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!