Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Lung cancer is a malignant tumor with high mortality rates. This study aims to develop potential candidates of integrin αvβ3 imaging agents, which can facilitate the diagnosis and treatment of lung cancer.
Methods: The T7 peptide was labeled with carbonyl technetium. The thin layer chromatography with acetone as the development system was performed to investigate the purity and stability of (99m)Tc-T7. The binding affinity of (99m)Tc-T7 with NCI-H157 tumor cells was determined. The biodistribution of (99m)Tc-T7 in nude mice bearing non-small cell lung carcinoma was observed after injection of (99m)Tc-T7 at 0.5 h, 1 h, 2 h, 4 h, and 8 h, and the radioactive ratio of tumor (T) and non-tumor tissues (NT) was calculated.
Results: 99mTc labeled T7 had high radiochemical purity of more than 90%, which does not require further purification, with good stability in vitro. The association and dissociation constant (KD) of (99m)Tc-T7 with NCI-H157 tumor cells was 196.1 nM. (99m)Tc-T7 was mainly metabolism through the internal organs with rapid blood removal. Moreover, the uptake in tumor tissue was significantly higher than the muscle with tumor/muscle ratio of 5.8. In addition, the (99m)Tc-T7 exhibited a transient accumulation in the lungs.
Conclusions: The (99m)Tc-T7 could be prepared using a simple method, had high labeling rate and good stability, and could be accumulated at tumor site. Thus, (99m)Tc-T7 is a potential lung cancer SPECT/CT imaging agent.